2003European Respiratory JournalOpen access

Face mask spirometry and respiratory pressures in normal subjects

M. Wohlgemuth, E.L. van der Kooi, Jan C.M. Hendriks, George W. Padberg, H.T.M. Folgering

Open full text 75 citations

Abstract

Spirometry and maximal respiratory pressures are pulmonary function parameters commonly used to evaluate respiratory function. Prediction values are available for conventional lung function devices using a standard tube or flanged type of mouthpiece connection. This equipment is not suitable for patients with facial or buccal muscle weakness, because of air leakage around the mouthpiece. A face mask was used for the portable lung function devices used in the neuromuscular department. The aim of this study was to compare the face mask and the conventional mouthpiece for the measurement of spirometry and of respiratory pressures in 22 healthy subjects. Values obtained with the conventional mouthpiece differed significantly from values obtained with the face mask. With the mask, forced vital capacity and forced expiratory volume in one second were 200 mL lower, and maximal expiratory pressure was 3.2 kPa lower than with the mouthpiece. Subsequently, new prediction values for face mask spirometry and maximal respiratory pressures were obtained from 252 other healthy subjects, from which new prediction equations were derived. It was concluded that the face mask connection to the lung function device is a valid alternative, is easy to use and is most useful to monitor changes in patients. This study confirms the importance of appropriate prediction equations, depending on subject-instrument interfaces.

Open-access reader

About this research paper

What this paper is about

Spirometry and maximal respiratory pressures are pulmonary function parameters commonly used to evaluate respiratory function. Prediction values are available for conventional lung function devices using a standard tube or flanged type of mouthpiece connection. This equipment is not suitable for patients with facial or buccal muscle weakness, because of air leakage around the mouthpiece. A face mask was used for the portable lung function devices used in the neuromuscular department. The aim of this study was to compare the face mask and the conventional mouthpiece for the measurement of spirometry and of respiratory pressures in 22 healthy subjects. Values obtained with the conventional mouthpiece differed significantly from values obtained with the face mask. With the mask, forced vital capacity and forced expiratory volume in one second were 200 mL lower, and maximal expiratory pressure was 3.2 kPa lower than with the mouthpiece. Subsequently, new prediction values for face mask spirometry and maximal respiratory pressures were obtained from 252 other healthy subjects, from which new prediction equations were derived. It was concluded that the face mask connection to the lung function device is a valid alternative, is easy to use and is most useful to monitor changes in patients. This study confirms the importance of appropriate prediction equations, depending on subject-instrument interfaces.

Why it matters

OpenAlex reports 75 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Spirometry and maximal respiratory pressures are pulmonary function parameters commonly used to evaluate respiratory function. Prediction values are available for conventional lung function devices using a standard tube or flanged type of mouthpiece connection. This equipment is not suitable for patients with facial or buccal muscle weakness, because of air leakage around the mouthpiece. A face mask was used for the portable lung function devices used in the neuromuscular department. The aim of this study was to compare the face mask and the conventional mouthpiece for the measurement of spirometry and of respiratory pressures in 22 healthy subjects. Values obtained with the conventional mouthpiece differed significantly from values obtained with the face mask. With the mask, forced vital capacity and forced expiratory volume in one second were 200 mL lower, and maximal expiratory pressure was 3.2 kPa lower than with the mouthpiece. Subsequently, new prediction values for face mask spirometry and maximal respiratory pressures were obtained from 252 other healthy subjects, from which new prediction equations were derived. It was concluded that the face mask connection to the lung function device is a valid alternative, is easy to use and is most useful to monitor changes in patients. This study confirms the importance of appropriate prediction equations, depending on subject-instrument interfaces.

Key concepts: Mouthpiece, Spirometry, Medicine, Lung volumes, Pulmonary function testing, Respiratory system, Lung function, Lung

Related papers

Back to paper searchBrowse research topicsOriginal source
Face mask spirometry and respiratory pressures in normal subjects — Research Paper | ScholarLens