2013Journal of Prosthodontic ResearchRequires access

A three-dimensional finite element analysis of the stress distribution on morse taper implants surface

Marcelo Bighetti Toniollo, Ana Paula Macedo, Renata Cristina Silveira Rodrigues, Ricardo Faria Ribeiro, Maria da Glória Chiarello de Mattos

Open publisher page 41 citations

Abstract

PURPOSE: This finite element analysis (FEA) compared stress distribution on external surface of different morse taper implants, varying implant bodies length and dimensions of metal-ceramic crowns in order to maintain the occlusal alignment. METHODS: Three-dimensional finite element (FE) models were designed representing a posterior left side segment of the mandible: group 0, 3 implants of 11 mm length; group 1, implants of 13 mm, 11 mm and 5mm length; group 2, 1 implant of 11 mm and 2 implants of 5mm length; group 3, 3 implants of 5mm length. The abutments heights were 3.5mm for 13 mm and 11 mm implants (regular) and 0.8mm for 5mm implants (short). Evaluation was performed on a computer program (Ansys software), with oblique loads of 365N for molars and 200 N for premolars, applied on ridges of cusps and grooves. RESULTS: Abutments with 0.8mm height generated less von Mises stresses compared with 3.5mm height. The use of short implants associated with bigger crowns concentrated higher stress distribution and stress values on the surface implants, principally on the vestibular side (oblique direction of the loads). The more distal implant concentrated higher stress. CONCLUSIONS: Moreover, these 5mm implants were positioned at the cortical bone level, which has higher elastic modulus and may have influenced at the stress distribution. However, despite the higher stresses, these implants were well able to withstand the applied forces.

About this research paper

What this paper is about

PURPOSE: This finite element analysis (FEA) compared stress distribution on external surface of different morse taper implants, varying implant bodies length and dimensions of metal-ceramic crowns in order to maintain the occlusal alignment. METHODS: Three-dimensional finite element (FE) models were designed representing a posterior left side segment of the mandible: group 0, 3 implants of 11 mm length; group 1, implants of 13 mm, 11 mm and 5mm length; group 2, 1 implant of 11 mm and 2 implants of 5mm length; group 3, 3 implants of 5mm length. The abutments heights were 3.5mm for 13 mm and 11 mm implants (regular) and 0.8mm for 5mm implants (short). Evaluation was performed on a computer program (Ansys software), with oblique loads of 365N for molars and 200 N for premolars, applied on ridges of cusps and grooves. RESULTS: Abutments with 0.8mm height generated less von Mises stresses compared with 3.5mm height. The use of short implants associated with bigger crowns concentrated higher stress distribution and stress values on the surface implants, principally on the vestibular side (oblique direction of the loads). The more distal implant concentrated higher stress. CONCLUSIONS: Moreover, these 5mm implants were positioned at the cortical bone level, which has higher elastic modulus and may have influenced at the stress distribution. However, despite the higher stresses, these implants were well able to withstand the applied forces.

Why it matters

OpenAlex reports 41 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

PURPOSE: This finite element analysis (FEA) compared stress distribution on external surface of different morse taper implants, varying implant bodies length and dimensions of metal-ceramic crowns in order to maintain the occlusal alignment. METHODS: Three-dimensional finite element (FE) models were designed representing a posterior left side segment of the mandible: group 0, 3 implants of 11 mm length; group 1, implants of 13 mm, 11 mm and 5mm length; group 2, 1 implant of 11 mm and 2 implants of 5mm length; group 3, 3 implants of 5mm length. The abutments heights were 3.5mm for 13 mm and 11 mm implants (regular) and 0.8mm for 5mm implants (short). Evaluation was performed on a computer program (Ansys software), with oblique loads of 365N for molars and 200 N for premolars, applied on ridges of cusps and grooves. RESULTS: Abutments with 0.8mm height generated less von Mises stresses compared with 3.5mm height. The use of short implants associated with bigger crowns concentrated higher stress distribution and stress values on the surface implants, principally on the vestibular side (oblique direction of the loads). The more distal implant concentrated higher stress. CONCLUSIONS: Moreover, these 5mm implants were positioned at the cortical bone level, which has higher elastic modulus and may have influenced at the stress distribution. However, despite the higher stresses, these implants were well able to withstand the applied forces.

Key concepts: Finite element method, Materials science, Surface (topology), Surface stress, Stress (linguistics), Distribution (mathematics), Geometry, Composite material

Related papers

Back to paper searchBrowse research topicsOriginal source
A three-dimensional finite element analysis of the stress distribution on morse taper implants surface — Research Paper | ScholarLens