Urine Protein Electrophoresis and Immunoelectrophoresis Using Unconcentrated or Minimally Concentrated Urine Samples

Anja C. Roden, Karen S. Lockington, Linda J. Tostrud, Jerry A. Katzmann

Open full text 19 citations

Abstract

Our objective was to evaluate a gel system that uses unconcentrated urine specimens for protein electrophoresis (PEL) and immunofixation electrophoresis (IFE) in patients with monoclonal gammopathies. For the study, 222 urine specimens were analyzed by our current PEL method (Helena Laboratories, Beaumont, TX) and by a system that recommends use of unconcentrated urine (Sebia, Norcross, GA). M protein concentrations were compared in the 43 cases with a measurable M spike. IFE was performed on 111 of the samples using both methods. There was a 97% concordance for detection of PEL abnormalities. The concordance for IFE was 98%. M protein concentrations by the 2 methods correlated well (r2=0.99; slope, 1.04). Cases with insufficient urine volumes for concentration (PEL, 7; IFE, 20) were analyzed in the Sebia gel system, and in 11 cases (PEL, 2; IFE, 9) an M protein was identified.High-resolution gel electrophoresis of urine using the Sebia system offers similar performance for detection, characterization, and quantification of M proteins when compared with our current gel system. Testing unconcentrated urine specimens will mean fewer sample rejections owing to insufficient sample volume.

Open-access reader

About this research paper

What this paper is about

Our objective was to evaluate a gel system that uses unconcentrated urine specimens for protein electrophoresis (PEL) and immunofixation electrophoresis (IFE) in patients with monoclonal gammopathies. For the study, 222 urine specimens were analyzed by our current PEL method (Helena Laboratories, Beaumont, TX) and by a system that recommends use of unconcentrated urine (Sebia, Norcross, GA). M protein concentrations were compared in the 43 cases with a measurable M spike. IFE was performed on 111 of the samples using both methods. There was a 97% concordance for detection of PEL abnormalities. The concordance for IFE was 98%. M protein concentrations by the 2 methods correlated well (r2=0.99; slope, 1.04). Cases with insufficient urine volumes for concentration (PEL, 7; IFE, 20) were analyzed in the Sebia gel system, and in 11 cases (PEL, 2; IFE, 9) an M protein was identified.High-resolution gel electrophoresis of urine using the Sebia system offers similar performance for detection, characterization, and quantification of M proteins when compared with our current gel system. Testing unconcentrated urine specimens will mean fewer sample rejections owing to insufficient sample volume.

Why it matters

OpenAlex reports 19 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Our objective was to evaluate a gel system that uses unconcentrated urine specimens for protein electrophoresis (PEL) and immunofixation electrophoresis (IFE) in patients with monoclonal gammopathies. For the study, 222 urine specimens were analyzed by our current PEL method (Helena Laboratories, Beaumont, TX) and by a system that recommends use of unconcentrated urine (Sebia, Norcross, GA). M protein concentrations were compared in the 43 cases with a measurable M spike. IFE was performed on 111 of the samples using both methods. There was a 97% concordance for detection of PEL abnormalities. The concordance for IFE was 98%. M protein concentrations by the 2 methods correlated well (r2=0.99; slope, 1.04). Cases with insufficient urine volumes for concentration (PEL, 7; IFE, 20) were analyzed in the Sebia gel system, and in 11 cases (PEL, 2; IFE, 9) an M protein was identified.High-resolution gel electrophoresis of urine using the Sebia system offers similar performance for detection, characterization, and quantification of M proteins when compared with our current gel system. Testing unconcentrated urine specimens will mean fewer sample rejections owing to insufficient sample volume.

Key concepts: Urine, Immunoelectrophoresis, Immunofixation, Concordance, Serum protein electrophoresis, Chromatography, Chemistry, Medicine

Related papers