2003•Journal of Analytical Atomic SpectrometryRequires access

Magnesium isotope heterogeneity of the isotopic standard SRM980 and new reference materials for magnesium-isotope-ratio measurements

Αlbert Galy, Olga Yoffe, P. E. Janney, Ross W. Williams, Christophe Cloquet, Olivier Alard, Ludwik Halicz, Meenakshi Wadhwa, I. D. Hutcheon, Erick C. Ramon, Jean Carignan

Open publisher page 461 citations

Abstract

Multicollector ICP-MS has been used for the precise measurement of variations in the isotopic composition of the isotopic standard of magnesium (SRM980) provided by the National Institute of Standards and Technology (Gaithersburg, MD, USA). The SRM980 consists of metal chips weighing between 1 and 50 mg and each unit delivered by the National Institute of Standards and Technology corresponds to a bottle containing about 0.3 g. Height units were analysed. Variations in sample 25Mg/24Mg, and 26Mg/24Mg ratios are expressed as δ25Mg and δ26Mg units, respectively, which are deviations in parts per 103 from the same ratio in a standard solution. The differences in δ25Mg and δ26Mg of the SRM980 are up to 4.20 and 8.19‰, respectively, while the long-term repeatability of δ25Mg and δ26Mg are 0.09 and 0.16‰, respectively, at 95% confidence. However, when plotted in a three-isotope diagram, all the data fall on a single mass fractionation line. Overall limits of error of the SRM980 reported here fall within the previously reported overall limits of error. The isotopic heterogeneity not only corresponds to differences among units but has been found at the chip-size level. This result, due to the precision of the MC-ICP-MS technique, makes the SRM980 inappropriate for the international isotopic standard of magnesium. The SRM980 can still be used to report the excess of 26Mg, which is defined by the deviation from the mass-dependent relationship between 25Mg/24Mg, and 26Mg/24Mg ratios. Two large batches (around 10 g of Mg in each) of pure Mg solutions (in 0.3 M HNO3) have been prepared and characterised. These 2 solutions (DSM3 and Cambridge 1) are suitable reference material because they are immune to heterogeneity. DSM3 and Cambridge 1 are isotopically different (by 1.3‰ per u) and are available upon request from the first author. In addition, DSM3 has an isotopic composition very similar to the Mg-isotopic composition of carbonaceous chondrites (Orgueil and Allende). Because of the lack of heterogeneity and the cosmochemical and geochemical significance of DSM3, we urge the use of DSM3 as the primary isotopic reference material to report Mg-isotopic variations.

About this research paper

What this paper is about

Multicollector ICP-MS has been used for the precise measurement of variations in the isotopic composition of the isotopic standard of magnesium (SRM980) provided by the National Institute of Standards and Technology (Gaithersburg, MD, USA). The SRM980 consists of metal chips weighing between 1 and 50 mg and each unit delivered by the National Institute of Standards and Technology corresponds to a bottle containing about 0.3 g. Height units were analysed. Variations in sample 25Mg/24Mg, and 26Mg/24Mg ratios are expressed as δ25Mg and δ26Mg units, respectively, which are deviations in parts per 103 from the same ratio in a standard solution. The differences in δ25Mg and δ26Mg of the SRM980 are up to 4.20 and 8.19‰, respectively, while the long-term repeatability of δ25Mg and δ26Mg are 0.09 and 0.16‰, respectively, at 95% confidence. However, when plotted in a three-isotope diagram, all the data fall on a single mass fractionation line. Overall limits of error of the SRM980 reported here fall within the previously reported overall limits of error. The isotopic heterogeneity not only corresponds to differences among units but has been found at the chip-size level. This result, due to the precision of the MC-ICP-MS technique, makes the SRM980 inappropriate for the international isotopic standard of magnesium. The SRM980 can still be used to report the excess of 26Mg, which is defined by the deviation from the mass-dependent relationship between 25Mg/24Mg, and 26Mg/24Mg ratios. Two large batches (around 10 g of Mg in each) of pure Mg solutions (in 0.3 M HNO3) have been prepared and characterised. These 2 solutions (DSM3 and Cambridge 1) are suitable reference material because they are immune to heterogeneity. DSM3 and Cambridge 1 are isotopically different (by 1.3‰ per u) and are available upon request from the first author. In addition, DSM3 has an isotopic composition very similar to the Mg-isotopic composition of carbonaceous chondrites (Orgueil and Allende). Because of the lack of heterogeneity and the cosmochemical and geochemical significance of DSM3, we urge the use of DSM3 as the primary isotopic reference material to report Mg-isotopic variations.

Why it matters

OpenAlex reports 461 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Multicollector ICP-MS has been used for the precise measurement of variations in the isotopic composition of the isotopic standard of magnesium (SRM980) provided by the National Institute of Standards and Technology (Gaithersburg, MD, USA). The SRM980 consists of metal chips weighing between 1 and 50 mg and each unit delivered by the National Institute of Standards and Technology corresponds to a bottle containing about 0.3 g. Height units were analysed. Variations in sample 25Mg/24Mg, and 26Mg/24Mg ratios are expressed as δ25Mg and δ26Mg units, respectively, which are deviations in parts per 103 from the same ratio in a standard solution. The differences in δ25Mg and δ26Mg of the SRM980 are up to 4.20 and 8.19‰, respectively, while the long-term repeatability of δ25Mg and δ26Mg are 0.09 and 0.16‰, respectively, at 95% confidence. However, when plotted in a three-isotope diagram, all the data fall on a single mass fractionation line. Overall limits of error of the SRM980 reported here fall within the previously reported overall limits of error. The isotopic heterogeneity not only corresponds to differences among units but has been found at the chip-size level. This result, due to the precision of the MC-ICP-MS technique, makes the SRM980 inappropriate for the international isotopic standard of magnesium. The SRM980 can still be used to report the excess of 26Mg, which is defined by the deviation from the mass-dependent relationship between 25Mg/24Mg, and 26Mg/24Mg ratios. Two large batches (around 10 g of Mg in each) of pure Mg solutions (in 0.3 M HNO3) have been prepared and characterised. These 2 solutions (DSM3 and Cambridge 1) are suitable reference material because they are immune to heterogeneity. DSM3 and Cambridge 1 are isotopically different (by 1.3‰ per u) and are available upon request from the first author. In addition, DSM3 has an isotopic composition very similar to the Mg-isotopic composition of carbonaceous chondrites (Orgueil and Allende). Because of the lack of heterogeneity and the cosmochemical and geochemical significance of DSM3, we urge the use of DSM3 as the primary isotopic reference material to report Mg-isotopic variations.

Key concepts: Isotope, Repeatability, Isotopes of magnesium, Magnesium, Standard deviation, Analytical Chemistry (journal), Stable isotope ratio, Fractionation

Related papers

Back to paper searchBrowse research topicsOriginal source
Magnesium isotope heterogeneity of the isotopic standard SRM980 and new reference materials for magnesium-isotope-ratio measurements — Research Paper | ScholarLens