2011Clinical ChemistryOpen access

Proficiency Testing/External Quality Assessment: Current Challenges and Future Directions

W. Greg Miller, Graham Jones, Gary L. Horowitz, Cas Weykamp

Open full text 336 citations

Abstract

BACKGROUND: Proficiency testing (PT), or external quality assessment (EQA), is intended to verify on a recurring basis that laboratory results conform to expectations for the quality required for patient care. CONTENT: Key factors for interpreting PT/EQA results are knowledge of the commutability of the samples used and the process used for target value assignment. A commutable PT/EQA sample demonstrates the same numeric relationship between different measurement procedures as that expected for patients' samples. Noncommutable PT/EQA samples frequently have a matrix-related bias of unknown magnitude that limits interpretation of results. PT/EQA results for commutable samples can be used to assess accuracy against a reference measurement procedure or a designated comparison method. In addition, the agreement of the results between different measurement procedures for commutable samples reflects that which would be seen for patients' samples. PT/EQA results for noncommutable samples must be compared to a peer group mean/median of results from participants who use measurement procedures that are expected to have the same or very similar matrix-related bias. Peer group evaluation is used to asses whether a laboratory is using a measurement procedure in conformance to the manufacturer's specifications and/or in conformance to other laboratories using the same technology. A noncommutable PT/EQA sample does not give meaningful information about the relationship of results for patients' samples between different measurement procedures. SUMMARY: PT/EQA provides substantial value to the practice of laboratory medicine by assessing the performance of individual laboratories and, when commutable samples are used, the status of standardization or harmonization among different measurement procedures.

Open-access reader

About this research paper

What this paper is about

BACKGROUND: Proficiency testing (PT), or external quality assessment (EQA), is intended to verify on a recurring basis that laboratory results conform to expectations for the quality required for patient care. CONTENT: Key factors for interpreting PT/EQA results are knowledge of the commutability of the samples used and the process used for target value assignment. A commutable PT/EQA sample demonstrates the same numeric relationship between different measurement procedures as that expected for patients' samples. Noncommutable PT/EQA samples frequently have a matrix-related bias of unknown magnitude that limits interpretation of results. PT/EQA results for commutable samples can be used to assess accuracy against a reference measurement procedure or a designated comparison method. In addition, the agreement of the results between different measurement procedures for commutable samples reflects that which would be seen for patients' samples. PT/EQA results for noncommutable samples must be compared to a peer group mean/median of results from participants who use measurement procedures that are expected to have the same or very similar matrix-related bias. Peer group evaluation is used to asses whether a laboratory is using a measurement procedure in conformance to the manufacturer's specifications and/or in conformance to other laboratories using the same technology. A noncommutable PT/EQA sample does not give meaningful information about the relationship of results for patients' samples between different measurement procedures. SUMMARY: PT/EQA provides substantial value to the practice of laboratory medicine by assessing the performance of individual laboratories and, when commutable samples are used, the status of standardization or harmonization among different measurement procedures.

Why it matters

OpenAlex reports 336 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

BACKGROUND: Proficiency testing (PT), or external quality assessment (EQA), is intended to verify on a recurring basis that laboratory results conform to expectations for the quality required for patient care. CONTENT: Key factors for interpreting PT/EQA results are knowledge of the commutability of the samples used and the process used for target value assignment. A commutable PT/EQA sample demonstrates the same numeric relationship between different measurement procedures as that expected for patients' samples. Noncommutable PT/EQA samples frequently have a matrix-related bias of unknown magnitude that limits interpretation of results. PT/EQA results for commutable samples can be used to assess accuracy against a reference measurement procedure or a designated comparison method. In addition, the agreement of the results between different measurement procedures for commutable samples reflects that which would be seen for patients' samples. PT/EQA results for noncommutable samples must be compared to a peer group mean/median of results from participants who use measurement procedures that are expected to have the same or very similar matrix-related bias. Peer group evaluation is used to asses whether a laboratory is using a measurement procedure in conformance to the manufacturer's specifications and/or in conformance to other laboratories using the same technology. A noncommutable PT/EQA sample does not give meaningful information about the relationship of results for patients' samples between different measurement procedures. SUMMARY: PT/EQA provides substantial value to the practice of laboratory medicine by assessing the performance of individual laboratories and, when commutable samples are used, the status of standardization or harmonization among different measurement procedures.

Key concepts: External quality assessment, Medical physics, Medicine, Sample (material), Medical laboratory, Quality assessment, Computer science, Statistics

Related papers

Back to paper searchBrowse research topicsOriginal source
Proficiency Testing/External Quality Assessment: Current Challenges and Future Directions — Research Paper | ScholarLens