1965•Clinical ChemistryRequires access

Evaluation of a Cellulose-Acetate Electrophoresis System for Serum Protein Fractionation

Alex Kaplan, John Savory

Open publisher page 61 citations

Abstract

Abstract A rapid system for the quantitative fractionation of serum proteins by electrophoresis on cellulose-acetate membranes was evaluated and found to be quite precise. The reproducibility (coefficient of variation) of the routine fractionation of a control serum carried out 40 times during a 15-week period was 2.4% for albumin and 14.2, 6.0, 6.1, and 5.2%, respectively, for the α1-, α2-, β-, and γ-globulin fractions. Normal values are given for serum protein fractions (specimens from nonprofessional blood donors) obtained by cellulose acetate electrophoresis.

About this research paper

What this paper is about

Abstract A rapid system for the quantitative fractionation of serum proteins by electrophoresis on cellulose-acetate membranes was evaluated and found to be quite precise. The reproducibility (coefficient of variation) of the routine fractionation of a control serum carried out 40 times during a 15-week period was 2.4% for albumin and 14.2, 6.0, 6.1, and 5.2%, respectively, for the α1-, α2-, β-, and γ-globulin fractions. Normal values are given for serum protein fractions (specimens from nonprofessional blood donors) obtained by cellulose acetate electrophoresis.

Why it matters

OpenAlex reports 61 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Abstract A rapid system for the quantitative fractionation of serum proteins by electrophoresis on cellulose-acetate membranes was evaluated and found to be quite precise. The reproducibility (coefficient of variation) of the routine fractionation of a control serum carried out 40 times during a 15-week period was 2.4% for albumin and 14.2, 6.0, 6.1, and 5.2%, respectively, for the α1-, α2-, β-, and γ-globulin fractions. Normal values are given for serum protein fractions (specimens from nonprofessional blood donors) obtained by cellulose acetate electrophoresis.

Key concepts: Fractionation, Chromatography, Cellulose acetate, Chemistry, Electrophoresis, Albumin, Globulin, Serum albumin

Related papers

Back to paper searchBrowse research topicsOriginal source
Evaluation of a Cellulose-Acetate Electrophoresis System for Serum Protein Fractionation — Research Paper | ScholarLens