QT dispersion is reduced after valve replacement in patients with aortic stenosis
Dawood Darbar, Cecile Cherry, David Kerins
Abstract
Open-access reader
Dawood Darbar, Cecile Cherry, David Kerins
Abstract
Open-access reader
OBJECTIVE: To investigate whether QT dispersion is a reliable index of the severity of aortic stenosis and left ventricular hypertrophy in the setting of aortic stenosis. DESIGN: A retrospective analysis of the results of echocardiography and electrocardiography before and after aortic valve replacement. SETTING: Tertiary centre. PATIENTS: 36 men (30 white and six black) with symptomatic aortic stenosis requiring valve replacement. RESULTS: All patients had significant aortic stenosis (mean (SD) aortic valve area 0.68 (0.18) cm2) and evidence of left ventricular hypertrophy (left ventricular mass index (LVMI): 267 (90) g/m2). Before aortic valve replacement, QT dispersion was correlated with mean aortic valve area and LVMI (r = 0.697, p < 0.001, and r = 0.59, p < 2.4 x 10(-6), respectively). QT dispersion and QT corrected for heart rate dispersion decreased from 133 (54) to 71 (33) ms and from 151 (64) to 94 (76) ms, respectively (p < 0.001 for both). LVMI regressed after aortic valve replacement to 190 (79) g/m2, p < 0.01. CONCLUSIONS: QT dispersion is increased in association with LVMI in patients with significant symptomatic aortic stenosis. Aortic valve replacement reduces QT dispersion and LVMI. QT dispersion could be a useful indicator of risk and risk reduction in patients with significant symptomatic aortic stenosis.
OpenAlex reports 25 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
OBJECTIVE: To investigate whether QT dispersion is a reliable index of the severity of aortic stenosis and left ventricular hypertrophy in the setting of aortic stenosis. DESIGN: A retrospective analysis of the results of echocardiography and electrocardiography before and after aortic valve replacement. SETTING: Tertiary centre. PATIENTS: 36 men (30 white and six black) with symptomatic aortic stenosis requiring valve replacement. RESULTS: All patients had significant aortic stenosis (mean (SD) aortic valve area 0.68 (0.18) cm2) and evidence of left ventricular hypertrophy (left ventricular mass index (LVMI): 267 (90) g/m2). Before aortic valve replacement, QT dispersion was correlated with mean aortic valve area and LVMI (r = 0.697, p < 0.001, and r = 0.59, p < 2.4 x 10(-6), respectively). QT dispersion and QT corrected for heart rate dispersion decreased from 133 (54) to 71 (33) ms and from 151 (64) to 94 (76) ms, respectively (p < 0.001 for both). LVMI regressed after aortic valve replacement to 190 (79) g/m2, p < 0.01. CONCLUSIONS: QT dispersion is increased in association with LVMI in patients with significant symptomatic aortic stenosis. Aortic valve replacement reduces QT dispersion and LVMI. QT dispersion could be a useful indicator of risk and risk reduction in patients with significant symptomatic aortic stenosis.
Key concepts: Medicine, Cardiology, Internal medicine, Stenosis, Left ventricular hypertrophy, Aortic valve replacement, Aortic valve stenosis, Aortic valve