2009•Caries ResearchRequires access

Hardness Tests on Sound Enamel and Artificially Demineralized White Spot Lesions

David J. Purdell-Lewis, A. B. Johan Groeneveld, J. J. A. Arends

Open publisher page 39 citations

Abstract

The accuracy and reproducability of hardness measurements have been investigated in this study. Sound and demineralized enamel were used as the main test materials. The reproducability of hardness measurements on artificial white spot lesions produced by a hydroxyethyl cellulose/lactic acid demineralizing solution was also investigated on embedded cross-sections. The operator error was found to be less than 5% when reading both steel and enamel indentations. The maximum hardness of the surface layer and the minimum hardness of the subsurface lesion were measured in three positions in each of 10 artificial white spot lesions. An analysis of the results showed that: (a) the hardness values at the same distance from the surface but in different areas of the same lesion were very similar; (b) hardness values between lesions were also very even; (c) the drop in hardness after demineralization was related to the initial hardness of the enamel.

About this research paper

What this paper is about

The accuracy and reproducability of hardness measurements have been investigated in this study. Sound and demineralized enamel were used as the main test materials. The reproducability of hardness measurements on artificial white spot lesions produced by a hydroxyethyl cellulose/lactic acid demineralizing solution was also investigated on embedded cross-sections. The operator error was found to be less than 5% when reading both steel and enamel indentations. The maximum hardness of the surface layer and the minimum hardness of the subsurface lesion were measured in three positions in each of 10 artificial white spot lesions. An analysis of the results showed that: (a) the hardness values at the same distance from the surface but in different areas of the same lesion were very similar; (b) hardness values between lesions were also very even; (c) the drop in hardness after demineralization was related to the initial hardness of the enamel.

Why it matters

OpenAlex reports 39 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The accuracy and reproducability of hardness measurements have been investigated in this study. Sound and demineralized enamel were used as the main test materials. The reproducability of hardness measurements on artificial white spot lesions produced by a hydroxyethyl cellulose/lactic acid demineralizing solution was also investigated on embedded cross-sections. The operator error was found to be less than 5% when reading both steel and enamel indentations. The maximum hardness of the surface layer and the minimum hardness of the subsurface lesion were measured in three positions in each of 10 artificial white spot lesions. An analysis of the results showed that: (a) the hardness values at the same distance from the surface but in different areas of the same lesion were very similar; (b) hardness values between lesions were also very even; (c) the drop in hardness after demineralization was related to the initial hardness of the enamel.

Key concepts: Enamel paint, Demineralization, Hardness, Materials science, Vickers hardness test, Indentation hardness, Lesion, Composite material

Related papers

Back to paper searchBrowse research topicsOriginal source
Hardness Tests on Sound Enamel and Artificially Demineralized White Spot Lesions — Research Paper | ScholarLens