Radioimmunoassay of Estriol-16-Glucuronide
Judith Sugar, Sophie Alexander, Cécile Dessy, J Schwers
Abstract
Judith Sugar, Sophie Alexander, Cécile Dessy, J Schwers
Abstract
A specific radioimmunoassay of estriol-16-glucuronide has been developed, using an antiserum obtained by immunization of rabbits against estriol-16-glucuronide-BSA. The assay does not require hydrolysis, extraction and purification, but only a dilution of the crude sample. This constitutes the main advantage of the precedure. Accuracy, precision and sensitivity of the method are similar to those reported for other radioimmunoassays of estriol. Its specificity is good for the measurement of estriol-16-glucuronide in urine and in amniotic fluid, but not in serum of pregnant women, which apparently contains material interfering with the radioimmunoassay, at dilutions of less than 1/100. A significant correlation was observed between estriol-16-glucuronide and total estriol in urine during pregnancy; however, the contribution of the glucuronide to the total increases as pregnancy progresses, rising from 50% for a total of 5 mg/24 h to 85% for a total of 50 mg/24 h. The present radioimmunoassay can be used as a quick and reliable method for the measurement of urinary estriol-16-glucuronide in high risk pregnancies.
OpenAlex reports 9 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
A specific radioimmunoassay of estriol-16-glucuronide has been developed, using an antiserum obtained by immunization of rabbits against estriol-16-glucuronide-BSA. The assay does not require hydrolysis, extraction and purification, but only a dilution of the crude sample. This constitutes the main advantage of the precedure. Accuracy, precision and sensitivity of the method are similar to those reported for other radioimmunoassays of estriol. Its specificity is good for the measurement of estriol-16-glucuronide in urine and in amniotic fluid, but not in serum of pregnant women, which apparently contains material interfering with the radioimmunoassay, at dilutions of less than 1/100. A significant correlation was observed between estriol-16-glucuronide and total estriol in urine during pregnancy; however, the contribution of the glucuronide to the total increases as pregnancy progresses, rising from 50% for a total of 5 mg/24 h to 85% for a total of 50 mg/24 h. The present radioimmunoassay can be used as a quick and reliable method for the measurement of urinary estriol-16-glucuronide in high risk pregnancies.
Key concepts: Radioimmunoassay, Estriol, Urine, Glucuronide, Chemistry, Chromatography, Endocrinology, Internal medicine