Hospital Indoor Environment: Screening for Micro-Organisms and Particulate Matter
Kateřina Klánová, Jitka Hollerová
Abstract
Kateřina Klánová, Jitka Hollerová
Abstract
The concentrations of air-borne micro-organisms and particulate matter were measured in the air and on solid surfaces in five rooms in a hospital. For comparison the same measurements were also made outdoors. The rooms were chosen because of their different needs in terms of indoor environment quality. The highest bacterial concentrations were found in the air of a patient's room that was `unventilated' other than through its doorway. Some of the rooms were supplied with filtered air. Compared to the rest, these rooms had the lowest microbial concentrations in their air but the highest on surfaces. A correlation was found between the count of the particulate size-range ≥1.0 μm and that of bacteria ( r=0.76) and between the count of the particulate size range ≥5.0 μm and those of bacteria ( r=0.88) and staphylococci ( r=0.80) in indoor air. No correlation was found between the particulate count and the mould count in the indoor air.
OpenAlex reports 31 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
The concentrations of air-borne micro-organisms and particulate matter were measured in the air and on solid surfaces in five rooms in a hospital. For comparison the same measurements were also made outdoors. The rooms were chosen because of their different needs in terms of indoor environment quality. The highest bacterial concentrations were found in the air of a patient's room that was `unventilated' other than through its doorway. Some of the rooms were supplied with filtered air. Compared to the rest, these rooms had the lowest microbial concentrations in their air but the highest on surfaces. A correlation was found between the count of the particulate size-range ≥1.0 μm and that of bacteria ( r=0.76) and between the count of the particulate size range ≥5.0 μm and those of bacteria ( r=0.88) and staphylococci ( r=0.80) in indoor air. No correlation was found between the particulate count and the mould count in the indoor air.
Key concepts: Particulates, Indoor air, Environmental science, Indoor air quality, Air quality index, Environmental chemistry, Environmental engineering, Chemistry