Low-voltage applications mounted on high-voltage towers may pose a safety problem in the low-voltage network when a flashover occurs over the high-voltage insulators. To study the effects experimentally, a 150 kV system was made available. On a high-voltage tower carrying a cellular phone base station, one phase insulator was shorted to the tower. A current of about 200 A was injected into that phase at a large distance. We measured the current distribution and the relevant voltages in the low-voltage net. The experimental current data agree with EMTP calculations. Appropriate measures to guarantee safety for persons and electronic equipment are discussed.

About this research paper

What this paper is about

Low-voltage applications mounted on high-voltage towers may pose a safety problem in the low-voltage network when a flashover occurs over the high-voltage insulators. To study the effects experimentally, a 150 kV system was made available. On a high-voltage tower carrying a cellular phone base station, one phase insulator was shorted to the tower. A current of about 200 A was injected into that phase at a large distance. We measured the current distribution and the relevant voltages in the low-voltage net. The experimental current data agree with EMTP calculations. Appropriate measures to guarantee safety for persons and electronic equipment are discussed.

Why it matters

OpenAlex reports 10 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Low-voltage applications mounted on high-voltage towers may pose a safety problem in the low-voltage network when a flashover occurs over the high-voltage insulators. To study the effects experimentally, a 150 kV system was made available. On a high-voltage tower carrying a cellular phone base station, one phase insulator was shorted to the tower. A current of about 200 A was injected into that phase at a large distance. We measured the current distribution and the relevant voltages in the low-voltage net. The experimental current data agree with EMTP calculations. Appropriate measures to guarantee safety for persons and electronic equipment are discussed.

Key concepts: Arc flash, Voltage, Insulator (electricity), Tower, Electrical engineering, GSM, Emtp, Low voltage

Related papers

Back to paper searchBrowse research topicsOriginal source
Safety Aspects of GSM Systems on High-Voltage Towers: An Experimental Analysis — Research Paper | ScholarLens