2015•Tropical Journal of Pharmaceutical ResearchOpen access

Development and Validation of Reversed Phase High Performance Liquid Chromatographic Method for Determination of Amlodipine

Mohamed Alaama, A. B. M. Helal Uddin, HJ Mohamad, NS Amiruddin, SA Abbas

Open full text 11 citations

Abstract

Purpose: To develop and validate a new sensitive and low-cost method for the analysis of amlodipine in tablet dosage form using reversed phase high performance liquid chromatography (RP-HPLC) with ultraviolet (UV) detection.Methods: Standards and samples were prepared by dissolving amlodipine besylate standard or amlodipine tablets in mobile phase and sonicated for 5 min. The samples were analysed by RP-HPLC equipped with quaternary pump and auto-injector. Separation was achieved using C18 column, and the mobile phase consisted of ammonium acetate buffer containing 0.02 % triethylamine TEA (pH = 4, adjusted using glacial acetic acid) and acetonitrile in the ratio 60:40 v/v. The flow rate was 1 ml/min and a UV detector was used for the detection of amlodipine at a wavelength of 248 nm. The method was validated according to International Conference of Harmonization (ICH) guidelines.Results: The retention time for amlodipine peak was 3.44 ± 0.41 min with a total run time of 6 min. The method was linear over the range of 0.5 - 40 μg/ml with coefficient of determination (R2) of 0.999. Recovery was 98.09 - 100.19 %, and the method showed high precision and repeatability. All validated parameters were within the range of ICH requirements.Conclusion: A new rapid sensitive and low-cost method has been developed and validated for the analysis of amlodipine in tablet dosage form.Keywords: Amlodipine, Recovery, Repeatability, Precision, Reversed phase high performance liquid chromatography, Validation

Open-access reader

About this research paper

What this paper is about

Purpose: To develop and validate a new sensitive and low-cost method for the analysis of amlodipine in tablet dosage form using reversed phase high performance liquid chromatography (RP-HPLC) with ultraviolet (UV) detection.Methods: Standards and samples were prepared by dissolving amlodipine besylate standard or amlodipine tablets in mobile phase and sonicated for 5 min. The samples were analysed by RP-HPLC equipped with quaternary pump and auto-injector. Separation was achieved using C18 column, and the mobile phase consisted of ammonium acetate buffer containing 0.02 % triethylamine TEA (pH = 4, adjusted using glacial acetic acid) and acetonitrile in the ratio 60:40 v/v. The flow rate was 1 ml/min and a UV detector was used for the detection of amlodipine at a wavelength of 248 nm. The method was validated according to International Conference of Harmonization (ICH) guidelines.Results: The retention time for amlodipine peak was 3.44 ± 0.41 min with a total run time of 6 min. The method was linear over the range of 0.5 - 40 μg/ml with coefficient of determination (R2) of 0.999. Recovery was 98.09 - 100.19 %, and the method showed high precision and repeatability. All validated parameters were within the range of ICH requirements.Conclusion: A new rapid sensitive and low-cost method has been developed and validated for the analysis of amlodipine in tablet dosage form.Keywords: Amlodipine, Recovery, Repeatability, Precision, Reversed phase high performance liquid chromatography, Validation

Why it matters

OpenAlex reports 11 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Purpose: To develop and validate a new sensitive and low-cost method for the analysis of amlodipine in tablet dosage form using reversed phase high performance liquid chromatography (RP-HPLC) with ultraviolet (UV) detection.Methods: Standards and samples were prepared by dissolving amlodipine besylate standard or amlodipine tablets in mobile phase and sonicated for 5 min. The samples were analysed by RP-HPLC equipped with quaternary pump and auto-injector. Separation was achieved using C18 column, and the mobile phase consisted of ammonium acetate buffer containing 0.02 % triethylamine TEA (pH = 4, adjusted using glacial acetic acid) and acetonitrile in the ratio 60:40 v/v. The flow rate was 1 ml/min and a UV detector was used for the detection of amlodipine at a wavelength of 248 nm. The method was validated according to International Conference of Harmonization (ICH) guidelines.Results: The retention time for amlodipine peak was 3.44 ± 0.41 min with a total run time of 6 min. The method was linear over the range of 0.5 - 40 μg/ml with coefficient of determination (R2) of 0.999. Recovery was 98.09 - 100.19 %, and the method showed high precision and repeatability. All validated parameters were within the range of ICH requirements.Conclusion: A new rapid sensitive and low-cost method has been developed and validated for the analysis of amlodipine in tablet dosage form.Keywords: Amlodipine, Recovery, Repeatability, Precision, Reversed phase high performance liquid chromatography, Validation

Key concepts: Amlodipine, Chromatography, Repeatability, High-performance liquid chromatography, Ammonium acetate, Chemistry, Triethylamine, Blood pressure

Related papers

Back to paper searchBrowse research topicsOriginal source
Development and Validation of Reversed Phase High Performance Liquid Chromatographic Method for Determination of Amlodipine — Research Paper | ScholarLens