2013Journal of Liquid Chromatography & Related TechnologiesRequires access

QUANTITATIVE ESTIMATION OF LUPEOL AND STIGMASTEROL IN COSTUS IGNEUS BY HIGH-PERFORMANCE THIN-LAYER CHROMATOGRAPHY

K. Manjula, K. Rajendran, T. Eevera, S. Kumaran

Open publisher page 16 citations

Abstract

In this article, simultaneous quantitative estimation of two biologically active triterpenoid compound Lupeol and a steroid compound, Stigmasterol, in Costus igneus stems was performed using high-performance thin-layer chromatography (HPTLC). TLC aluminum plates precoated with silica-gel 60 F254(20 cm × 10 cm) were used with a mobile phase of n-Hexane: Ethyl acetate (80:20v/v) for lupeol, Toluene: Acetone: Acetic acid (8.9: 0.9: 0.2 v/v/v) for stigmasterol and densitometric determination of these compounds was carried out at 366 nm in reflectance/absorbance mode. The linear regression data for the calibration plots showed a good linear relationship with r = 0.99794 and r = 0.99291 for Lupeol and Stigmasterol, respectively. A recovery study was carried out to check the accuracy of the method. The average recovery of Lupeol and Stigmasterol was 100.16% and 99.94%, respectively. According to International Conference on Harmonization (ICH) guidelines, the method was validated for linearity, precision, accuracy, and recovery, limit of detection, limit of quantification, specificity, robustness, and ruggedness. The HPTLC method was found to be reproducible, accurate, and precise and could detect these two compounds at nanogram level from the stem of Costus igneus.

About this research paper

What this paper is about

In this article, simultaneous quantitative estimation of two biologically active triterpenoid compound Lupeol and a steroid compound, Stigmasterol, in Costus igneus stems was performed using high-performance thin-layer chromatography (HPTLC). TLC aluminum plates precoated with silica-gel 60 F254(20 cm × 10 cm) were used with a mobile phase of n-Hexane: Ethyl acetate (80:20v/v) for lupeol, Toluene: Acetone: Acetic acid (8.9: 0.9: 0.2 v/v/v) for stigmasterol and densitometric determination of these compounds was carried out at 366 nm in reflectance/absorbance mode. The linear regression data for the calibration plots showed a good linear relationship with r = 0.99794 and r = 0.99291 for Lupeol and Stigmasterol, respectively. A recovery study was carried out to check the accuracy of the method. The average recovery of Lupeol and Stigmasterol was 100.16% and 99.94%, respectively. According to International Conference on Harmonization (ICH) guidelines, the method was validated for linearity, precision, accuracy, and recovery, limit of detection, limit of quantification, specificity, robustness, and ruggedness. The HPTLC method was found to be reproducible, accurate, and precise and could detect these two compounds at nanogram level from the stem of Costus igneus.

Why it matters

OpenAlex reports 16 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

In this article, simultaneous quantitative estimation of two biologically active triterpenoid compound Lupeol and a steroid compound, Stigmasterol, in Costus igneus stems was performed using high-performance thin-layer chromatography (HPTLC). TLC aluminum plates precoated with silica-gel 60 F254(20 cm × 10 cm) were used with a mobile phase of n-Hexane: Ethyl acetate (80:20v/v) for lupeol, Toluene: Acetone: Acetic acid (8.9: 0.9: 0.2 v/v/v) for stigmasterol and densitometric determination of these compounds was carried out at 366 nm in reflectance/absorbance mode. The linear regression data for the calibration plots showed a good linear relationship with r = 0.99794 and r = 0.99291 for Lupeol and Stigmasterol, respectively. A recovery study was carried out to check the accuracy of the method. The average recovery of Lupeol and Stigmasterol was 100.16% and 99.94%, respectively. According to International Conference on Harmonization (ICH) guidelines, the method was validated for linearity, precision, accuracy, and recovery, limit of detection, limit of quantification, specificity, robustness, and ruggedness. The HPTLC method was found to be reproducible, accurate, and precise and could detect these two compounds at nanogram level from the stem of Costus igneus.

Key concepts: Lupeol, Stigmasterol, Chemistry, Chromatography, Silica gel, High performance thin layer chromatography, Ethyl acetate, Detection limit

Related papers

Back to paper searchBrowse research topicsOriginal source
QUANTITATIVE ESTIMATION OF LUPEOL AND STIGMASTEROL IN COSTUS IGNEUS BY HIGH-PERFORMANCE THIN-LAYER CHROMATOGRAPHY — Research Paper | ScholarLens