2014•DOAJ (DOAJ: Directory of Open Access Journals)Requires access

Radiographic outcomes of distal radius fractures treated by close reduction and external fixation with and without percutaneous pins

A Dasht Bozorg, Seyed Abdolhossein Mehdi Nasab, Ehsan Alimi

Open publisher page 0 citations

Abstract

Background: External fixator is anappropriate device for the treatment of comminuted distal radius fractures, but there is no consensus about simultaneous supplementary percutaneous pinning. The present study was conducted to determine the short-term outcomes of comminuted distal radius fracture treated by close reduction and external fixation with and without supplementary pinning. \nMethods: This prospective study was carried out on 62 patients with distal radius fracture type III. All consecutive patients were treated by close reduction and External Fixator (EXF) (N=30) and close reduction, External Fixator (EXF) with supplemental percutaneous pinning (N=32). Radiographic images of the wrist were takenbefore treatment and 1 week, 3 weeks and3 months after treatment. \nResults: There was no significant difference between the Dorsiflexion (DF)means of the wrist in the pin (43.5±9.2) and no-pin (41.3±6.9) groups (P=0.099). There was also a significant difference between the Palmar Flexion (PF) means of the wrist in the pin (50.8±8.6) and no-pin (48.3±10.6) groups (p=0.041). Further, the means of wrist extension in the no-pin and pin groups were 16.3° and 17.2°, respectively, and for the wrist flexion in the no-pin and pin groups were 22° and 13.6°, respectively. The means of radial length difference in the pin and no-pin groups were 1.5 and 1.6 mm, respectively. Moreover, no significant difference was observed between radiographic indices of Radial Inclination (RI) and Volar Tilt (VT) in both groups. \nConclusions: Insertion of percutaneous pinning did not contribute to the improvement of comminuted distal radius fractures treated with external fixator.

About this research paper

What this paper is about

Background: External fixator is anappropriate device for the treatment of comminuted distal radius fractures, but there is no consensus about simultaneous supplementary percutaneous pinning. The present study was conducted to determine the short-term outcomes of comminuted distal radius fracture treated by close reduction and external fixation with and without supplementary pinning. \nMethods: This prospective study was carried out on 62 patients with distal radius fracture type III. All consecutive patients were treated by close reduction and External Fixator (EXF) (N=30) and close reduction, External Fixator (EXF) with supplemental percutaneous pinning (N=32). Radiographic images of the wrist were takenbefore treatment and 1 week, 3 weeks and3 months after treatment. \nResults: There was no significant difference between the Dorsiflexion (DF)means of the wrist in the pin (43.5±9.2) and no-pin (41.3±6.9) groups (P=0.099). There was also a significant difference between the Palmar Flexion (PF) means of the wrist in the pin (50.8±8.6) and no-pin (48.3±10.6) groups (p=0.041). Further, the means of wrist extension in the no-pin and pin groups were 16.3° and 17.2°, respectively, and for the wrist flexion in the no-pin and pin groups were 22° and 13.6°, respectively. The means of radial length difference in the pin and no-pin groups were 1.5 and 1.6 mm, respectively. Moreover, no significant difference was observed between radiographic indices of Radial Inclination (RI) and Volar Tilt (VT) in both groups. \nConclusions: Insertion of percutaneous pinning did not contribute to the improvement of comminuted distal radius fractures treated with external fixator.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Background: External fixator is anappropriate device for the treatment of comminuted distal radius fractures, but there is no consensus about simultaneous supplementary percutaneous pinning. The present study was conducted to determine the short-term outcomes of comminuted distal radius fracture treated by close reduction and external fixation with and without supplementary pinning. \nMethods: This prospective study was carried out on 62 patients with distal radius fracture type III. All consecutive patients were treated by close reduction and External Fixator (EXF) (N=30) and close reduction, External Fixator (EXF) with supplemental percutaneous pinning (N=32). Radiographic images of the wrist were takenbefore treatment and 1 week, 3 weeks and3 months after treatment. \nResults: There was no significant difference between the Dorsiflexion (DF)means of the wrist in the pin (43.5±9.2) and no-pin (41.3±6.9) groups (P=0.099). There was also a significant difference between the Palmar Flexion (PF) means of the wrist in the pin (50.8±8.6) and no-pin (48.3±10.6) groups (p=0.041). Further, the means of wrist extension in the no-pin and pin groups were 16.3° and 17.2°, respectively, and for the wrist flexion in the no-pin and pin groups were 22° and 13.6°, respectively. The means of radial length difference in the pin and no-pin groups were 1.5 and 1.6 mm, respectively. Moreover, no significant difference was observed between radiographic indices of Radial Inclination (RI) and Volar Tilt (VT) in both groups. \nConclusions: Insertion of percutaneous pinning did not contribute to the improvement of comminuted distal radius fractures treated with external fixator.

Key concepts: Medicine, Wrist, Percutaneous pinning, External fixation, Radiography, External fixator, Percutaneous, Significant difference

Related papers

Back to paper searchBrowse research topicsOriginal source
Radiographic outcomes of distal radius fractures treated by close reduction and external fixation with and without percutaneous pins — Research Paper | ScholarLens