2012•Applied Mechanics and MaterialsOpen access

On the Optimization of Vent Arrangement in a Subway Station

Atta Sojoudi, Farbod Vakilimoghaddam, Reihaneh Neishapouri

Open full text 0 citations

Abstract

Toxic gases resulted from fire events in subways stations are more dangerous than high temperature radiation from it. So, a well designed smoke exhaust system must be installed in subway station to control the smoke’s propagation and discharging. Smoke extraction in subway station depends on the duct laid above the ceiling, so vents are situated in the same level of platform layer’s ceiling. If subway station catches fire, smoke will cumulate in smoke reservoirs at the beginning and mechanical fan cannot exhaust any smoke in this process. In This paper, FDS 5.0 is used to simulate smoke’s movement in a side platform of an actual subway station in case of a fire. Simulations are carried out at the same volume flux of mechanical fan to investigate the effects of height of vents and depth of smoke reservoirs.

About this research paper

What this paper is about

Toxic gases resulted from fire events in subways stations are more dangerous than high temperature radiation from it. So, a well designed smoke exhaust system must be installed in subway station to control the smoke’s propagation and discharging. Smoke extraction in subway station depends on the duct laid above the ceiling, so vents are situated in the same level of platform layer’s ceiling. If subway station catches fire, smoke will cumulate in smoke reservoirs at the beginning and mechanical fan cannot exhaust any smoke in this process. In This paper, FDS 5.0 is used to simulate smoke’s movement in a side platform of an actual subway station in case of a fire. Simulations are carried out at the same volume flux of mechanical fan to investigate the effects of height of vents and depth of smoke reservoirs.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Toxic gases resulted from fire events in subways stations are more dangerous than high temperature radiation from it. So, a well designed smoke exhaust system must be installed in subway station to control the smoke’s propagation and discharging. Smoke extraction in subway station depends on the duct laid above the ceiling, so vents are situated in the same level of platform layer’s ceiling. If subway station catches fire, smoke will cumulate in smoke reservoirs at the beginning and mechanical fan cannot exhaust any smoke in this process. In This paper, FDS 5.0 is used to simulate smoke’s movement in a side platform of an actual subway station in case of a fire. Simulations are carried out at the same volume flux of mechanical fan to investigate the effects of height of vents and depth of smoke reservoirs.

Key concepts: Smoke, Ceiling (cloud), Subway station, Duct (anatomy), Marine engineering, Engineering, Environmental science, Waste management