National Dam Safety Program. Welton Ideker Dam (MO 11010), Missouri - Nemaha - Nodaway Basin, Holt County, Missouri. Phase I Inspection Report.

Rey S Decker, Gordon Jamison, Garold Ulmer, Harold P Hoskins

Open publisher page 0 citations

Abstract

Welton Ideker Dam was inspected by an interdisciplinary team of engineers. The purpose of the inspection was to make an assessment of the general condition of the dam with respect to safety, based upon available data and visual inspection, in order to determine if the dam poses hazards to human life or property. Our inspection and evaluation indicates that the spillway does not meet the criteria set forth in the recommended guidelines for a small dam having a high hazard potential. Considering the small volume of water impounded, the nature of the downstream channel and the hazards involved, one-half of the Probable Maximum Flood is the appropriate spillway design flood. The spillway will not pass the 100-year flood (flood having a one percent chance of being exceeded in any year) without overtopping the dam. The spillway will pass 9% of the Probable Maximum Flood as well as the 10-year flood without overtopping the dam. The Probable Maximum Flood (PMF) is defined as the flood that may be expected from the most severe combination of critical meteorologic and hydrologic conditions that are reasonably possible in the region.

About this research paper

What this paper is about

Welton Ideker Dam was inspected by an interdisciplinary team of engineers. The purpose of the inspection was to make an assessment of the general condition of the dam with respect to safety, based upon available data and visual inspection, in order to determine if the dam poses hazards to human life or property. Our inspection and evaluation indicates that the spillway does not meet the criteria set forth in the recommended guidelines for a small dam having a high hazard potential. Considering the small volume of water impounded, the nature of the downstream channel and the hazards involved, one-half of the Probable Maximum Flood is the appropriate spillway design flood. The spillway will not pass the 100-year flood (flood having a one percent chance of being exceeded in any year) without overtopping the dam. The spillway will pass 9% of the Probable Maximum Flood as well as the 10-year flood without overtopping the dam. The Probable Maximum Flood (PMF) is defined as the flood that may be expected from the most severe combination of critical meteorologic and hydrologic conditions that are reasonably possible in the region.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Welton Ideker Dam was inspected by an interdisciplinary team of engineers. The purpose of the inspection was to make an assessment of the general condition of the dam with respect to safety, based upon available data and visual inspection, in order to determine if the dam poses hazards to human life or property. Our inspection and evaluation indicates that the spillway does not meet the criteria set forth in the recommended guidelines for a small dam having a high hazard potential. Considering the small volume of water impounded, the nature of the downstream channel and the hazards involved, one-half of the Probable Maximum Flood is the appropriate spillway design flood. The spillway will not pass the 100-year flood (flood having a one percent chance of being exceeded in any year) without overtopping the dam. The spillway will pass 9% of the Probable Maximum Flood as well as the 10-year flood without overtopping the dam. The Probable Maximum Flood (PMF) is defined as the flood that may be expected from the most severe combination of critical meteorologic and hydrologic conditions that are reasonably possible in the region.

Key concepts: Spillway, Flood myth, Dam failure, Detention basin, Hydrology (agriculture), Flood stage, Environmental science, Dam break

Related papers

Back to paper searchBrowse research topicsOriginal source
National Dam Safety Program. Welton Ideker Dam (MO 11010), Missouri - Nemaha - Nodaway Basin, Holt County, Missouri. Phase I Inspection Report. — Research Paper | ScholarLens