2004•CirculationOpen access

Effect of Isthmus Anatomy and Ablation Catheter on Radiofrequency Catheter Ablation of the Cavotricuspid Isthmus

Antoine Da Costa, Emmanuel Faure, Jérôme Thévenin, Marc Messier, Samuel Bernard, Abdel Kihel, Christophe Robin, Cécile Romeyer, Karl Isaaz

Open full text 130 citations

Abstract

BACKGROUND: Cavotricuspid isthmus (CTI) characteristics are rarely documented when comparing catheters in radiofrequency ablation (RFA) of atrial flutter (AFL). Our objectives were (1) to evaluate the impact of CTI morphology and length on ablation procedures and (2) to compare the efficacy of an 8-mm-tip catheter with an irrigated cooled-tip RFA in the subgroup presumed to be more difficult to treat (with a long CTI, >35 mm). METHODS AND RESULTS: Over a period of 17 months, 185 patients accepted the protocol and underwent an isthmogram in preparation for RFA. Groups were classified according to CTI length and CTI morphology. RFA was performed with an 8-mm-tip catheter for patients with a short CTI, < or =35 mm (n=123), whereas randomization between an 8-mm-tip and a cooled-tip catheter applied to patients with a longer CTI, >35 mm (n=62). For long CTI, 32 patients were assigned to an 8-mm catheter and 30 patients to the cooled-tip RFA ablation group. In this subset, RF application (18.2+/-17 versus 19+/-13 minutes) and x-ray exposure (20.8+/-18 versus 18+/-13 minutes) did not differ between the 8-mm-tip and the cooled-tip procedures. Number of applications (9.9+/-11 versus 18.6+/-15 minutes; P<0.0001) and x-ray exposure (11.7+/-11 versus 19.5+/-16 minutes, P=0.0001) differed significantly between patients with short and long CTIs. Patients with short and straight CTIs required 3 times fewer RFA applications and shorter x-ray exposure compared with other CTI morphologies (pouch-like recesses and concave characteristics). CONCLUSIONS: The number of RF applications required for a complete isthmus block in long CTIs is not influenced by the choice between an 8-mm or cooled-tip catheter. Procedure parameters, however, are significantly influenced by CTI length and morphology. Pouch-like recesses and concave characteristics account for much longer ablation times at all CTI lengths.

Open-access reader

About this research paper

What this paper is about

BACKGROUND: Cavotricuspid isthmus (CTI) characteristics are rarely documented when comparing catheters in radiofrequency ablation (RFA) of atrial flutter (AFL). Our objectives were (1) to evaluate the impact of CTI morphology and length on ablation procedures and (2) to compare the efficacy of an 8-mm-tip catheter with an irrigated cooled-tip RFA in the subgroup presumed to be more difficult to treat (with a long CTI, >35 mm). METHODS AND RESULTS: Over a period of 17 months, 185 patients accepted the protocol and underwent an isthmogram in preparation for RFA. Groups were classified according to CTI length and CTI morphology. RFA was performed with an 8-mm-tip catheter for patients with a short CTI, < or =35 mm (n=123), whereas randomization between an 8-mm-tip and a cooled-tip catheter applied to patients with a longer CTI, >35 mm (n=62). For long CTI, 32 patients were assigned to an 8-mm catheter and 30 patients to the cooled-tip RFA ablation group. In this subset, RF application (18.2+/-17 versus 19+/-13 minutes) and x-ray exposure (20.8+/-18 versus 18+/-13 minutes) did not differ between the 8-mm-tip and the cooled-tip procedures. Number of applications (9.9+/-11 versus 18.6+/-15 minutes; P<0.0001) and x-ray exposure (11.7+/-11 versus 19.5+/-16 minutes, P=0.0001) differed significantly between patients with short and long CTIs. Patients with short and straight CTIs required 3 times fewer RFA applications and shorter x-ray exposure compared with other CTI morphologies (pouch-like recesses and concave characteristics). CONCLUSIONS: The number of RF applications required for a complete isthmus block in long CTIs is not influenced by the choice between an 8-mm or cooled-tip catheter. Procedure parameters, however, are significantly influenced by CTI length and morphology. Pouch-like recesses and concave characteristics account for much longer ablation times at all CTI lengths.

Why it matters

OpenAlex reports 130 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

BACKGROUND: Cavotricuspid isthmus (CTI) characteristics are rarely documented when comparing catheters in radiofrequency ablation (RFA) of atrial flutter (AFL). Our objectives were (1) to evaluate the impact of CTI morphology and length on ablation procedures and (2) to compare the efficacy of an 8-mm-tip catheter with an irrigated cooled-tip RFA in the subgroup presumed to be more difficult to treat (with a long CTI, >35 mm). METHODS AND RESULTS: Over a period of 17 months, 185 patients accepted the protocol and underwent an isthmogram in preparation for RFA. Groups were classified according to CTI length and CTI morphology. RFA was performed with an 8-mm-tip catheter for patients with a short CTI, < or =35 mm (n=123), whereas randomization between an 8-mm-tip and a cooled-tip catheter applied to patients with a longer CTI, >35 mm (n=62). For long CTI, 32 patients were assigned to an 8-mm catheter and 30 patients to the cooled-tip RFA ablation group. In this subset, RF application (18.2+/-17 versus 19+/-13 minutes) and x-ray exposure (20.8+/-18 versus 18+/-13 minutes) did not differ between the 8-mm-tip and the cooled-tip procedures. Number of applications (9.9+/-11 versus 18.6+/-15 minutes; P<0.0001) and x-ray exposure (11.7+/-11 versus 19.5+/-16 minutes, P=0.0001) differed significantly between patients with short and long CTIs. Patients with short and straight CTIs required 3 times fewer RFA applications and shorter x-ray exposure compared with other CTI morphologies (pouch-like recesses and concave characteristics). CONCLUSIONS: The number of RF applications required for a complete isthmus block in long CTIs is not influenced by the choice between an 8-mm or cooled-tip catheter. Procedure parameters, however, are significantly influenced by CTI length and morphology. Pouch-like recesses and concave characteristics account for much longer ablation times at all CTI lengths.

Key concepts: Medicine, Ablation, Catheter ablation, Catheter, Radiofrequency ablation, Anatomy, Radiofrequency catheter ablation, Surgery

Related papers

Back to paper searchBrowse research topicsOriginal source
Effect of Isthmus Anatomy and Ablation Catheter on Radiofrequency Catheter Ablation of the Cavotricuspid Isthmus — Research Paper | ScholarLens