1997•RadiologyRequires access

Pulmonary embolism: prospective comparison of spiral CT with ventilation-perfusion scintigraphy.

John Robert Mayo, Martine Rémy‐Jardin, N L Müller, Jacques Rémy, Daniel F. Worsley, Claude Hossein-Foucher, Justin Kwong, Maura J. Brown

Open publisher page 400 citations

Abstract

PURPOSE: To compare prospectively the accuracy of spiral computed tomography (CT) with that of ventilation-perfusion scintigraphy for diagnosing pulmonary embolism. MATERIALS AND METHODS: Within 48 hours of presentation, 142 patients suspected of having pulmonary embolism underwent spiral CT, scintigraphy, and (when indicated) pulmonary angiography. Pulmonary angiography was attempted if interpretations of spiral CT scans and of scintigrams were discordant or indeterminate and intermediate-probability, respectively. RESULTS: In the 139 patients who completed the study, interpretations of spiral CT scans and of scintigrams were concordant in 103 patients (29 with embolism, 74 without). In 20 patients, intermediate-probability scintigrams were interpreted (six with embolism at angiography, 14 without); diagnosis with spiral CT was correct in 16. Interpretations of spiral CT scans and those of scintigrams were discordant in 12 cases; diagnosis with spiral CT was correct in 11 cases and that with scintigraphy was correct in one. Spiral CT and scintigraphic scans of four patients with embolism did not show embolism. Sensitivities, specificities, and kappa values with spiral CT and scintigraphy were 87%, 95%, and 0.85 and 65%, 94%, and 0.61, respectively. CONCLUSION: In cases of pulmonary embolism, sensitivity of spiral CT is greater than that of scintigraphy. Interobserver agreement is better with spiral CT.

About this research paper

What this paper is about

PURPOSE: To compare prospectively the accuracy of spiral computed tomography (CT) with that of ventilation-perfusion scintigraphy for diagnosing pulmonary embolism. MATERIALS AND METHODS: Within 48 hours of presentation, 142 patients suspected of having pulmonary embolism underwent spiral CT, scintigraphy, and (when indicated) pulmonary angiography. Pulmonary angiography was attempted if interpretations of spiral CT scans and of scintigrams were discordant or indeterminate and intermediate-probability, respectively. RESULTS: In the 139 patients who completed the study, interpretations of spiral CT scans and of scintigrams were concordant in 103 patients (29 with embolism, 74 without). In 20 patients, intermediate-probability scintigrams were interpreted (six with embolism at angiography, 14 without); diagnosis with spiral CT was correct in 16. Interpretations of spiral CT scans and those of scintigrams were discordant in 12 cases; diagnosis with spiral CT was correct in 11 cases and that with scintigraphy was correct in one. Spiral CT and scintigraphic scans of four patients with embolism did not show embolism. Sensitivities, specificities, and kappa values with spiral CT and scintigraphy were 87%, 95%, and 0.85 and 65%, 94%, and 0.61, respectively. CONCLUSION: In cases of pulmonary embolism, sensitivity of spiral CT is greater than that of scintigraphy. Interobserver agreement is better with spiral CT.

Why it matters

OpenAlex reports 400 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

PURPOSE: To compare prospectively the accuracy of spiral computed tomography (CT) with that of ventilation-perfusion scintigraphy for diagnosing pulmonary embolism. MATERIALS AND METHODS: Within 48 hours of presentation, 142 patients suspected of having pulmonary embolism underwent spiral CT, scintigraphy, and (when indicated) pulmonary angiography. Pulmonary angiography was attempted if interpretations of spiral CT scans and of scintigrams were discordant or indeterminate and intermediate-probability, respectively. RESULTS: In the 139 patients who completed the study, interpretations of spiral CT scans and of scintigrams were concordant in 103 patients (29 with embolism, 74 without). In 20 patients, intermediate-probability scintigrams were interpreted (six with embolism at angiography, 14 without); diagnosis with spiral CT was correct in 16. Interpretations of spiral CT scans and those of scintigrams were discordant in 12 cases; diagnosis with spiral CT was correct in 11 cases and that with scintigraphy was correct in one. Spiral CT and scintigraphic scans of four patients with embolism did not show embolism. Sensitivities, specificities, and kappa values with spiral CT and scintigraphy were 87%, 95%, and 0.85 and 65%, 94%, and 0.61, respectively. CONCLUSION: In cases of pulmonary embolism, sensitivity of spiral CT is greater than that of scintigraphy. Interobserver agreement is better with spiral CT.

Key concepts: Medicine, Pulmonary embolism, Scintigraphy, Spiral computed tomography, Radiology, Pulmonary angiography, Spiral (railway), Angiography

Related papers

Back to paper searchBrowse research topicsOriginal source
Pulmonary embolism: prospective comparison of spiral CT with ventilation-perfusion scintigraphy. — Research Paper | ScholarLens