1970Applied OpticsRequires access

The Efficient Use of Photomultiplier Tubes for Recording Spectra

J. Rolfe, Steve Moore

Open publisher page 31 citations

Abstract

The experimental value of the signal-to-noise ratio (S/N) was used as a criterion for comparing different photomultiplier tubes and for assessing the relative merits of pulse-counting and dc measurement. For tubes with S-11 and S-20 photocathodes at room temperature, no significant difference was found between pulse-counting and dc methods. When different tubes were compared, other factors being equal, those with smaller cathodes gave higher S/N values. A comparison was also made between a cooled S-1 cathode photomultiplier tube and a p-i-n photodiode at room temperature. The photomultiplier tube was found to have a S/N many times higher than the photodiode.

About this research paper

What this paper is about

The experimental value of the signal-to-noise ratio (S/N) was used as a criterion for comparing different photomultiplier tubes and for assessing the relative merits of pulse-counting and dc measurement. For tubes with S-11 and S-20 photocathodes at room temperature, no significant difference was found between pulse-counting and dc methods. When different tubes were compared, other factors being equal, those with smaller cathodes gave higher S/N values. A comparison was also made between a cooled S-1 cathode photomultiplier tube and a p-i-n photodiode at room temperature. The photomultiplier tube was found to have a S/N many times higher than the photodiode.

Why it matters

OpenAlex reports 31 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The experimental value of the signal-to-noise ratio (S/N) was used as a criterion for comparing different photomultiplier tubes and for assessing the relative merits of pulse-counting and dc measurement. For tubes with S-11 and S-20 photocathodes at room temperature, no significant difference was found between pulse-counting and dc methods. When different tubes were compared, other factors being equal, those with smaller cathodes gave higher S/N values. A comparison was also made between a cooled S-1 cathode photomultiplier tube and a p-i-n photodiode at room temperature. The photomultiplier tube was found to have a S/N many times higher than the photodiode.

Key concepts: Photomultiplier, Optics, Photodiode, Materials science, Photon counting, Tube (container), Cathode, Physics

Related papers

Back to paper searchBrowse research topicsOriginal source
The Efficient Use of Photomultiplier Tubes for Recording Spectra — Research Paper | ScholarLens