Automated amidolytic method for determining heparin, a heparinoid, and a low-Mr heparin fragment, based on their anti-Xa activity.
Hugo Ten Cate, R. J. Lamping, C. P. Henny, A Prins, J W ten Cate
Abstract
Hugo Ten Cate, R. J. Lamping, C. P. Henny, A Prins, J W ten Cate
Abstract
Using the chromogenic substrate S-2222, we have optimized and automated an amidolytic assay for heparin. The assay is based on the detection of anti-Xa activity generated by heparin in plasma. The method is reproducible (intra- and interassay CVs of 2.4 and 3.3%, respectively) and reliable in antithrombin III-deficient plasma. Results of this assay, obtained for plasma samples from patients and volunteers treated with heparin, correlate well (r = 0.899) with those of the test for activated partial thromboplastin time. Upon administration of a low-Mr heparinoid (Org 10172) and heparin fragment ( Kabi 2165), however, the activated partial thromboplastin time failed to detect anticoagulant activity, whereas the chromogenic heparin assay revealed anti-Xa activity. This automated amidolytic assay for heparin is therefore suitable not only for monitoring standard therapy with heparin but also for measuring the activity of recently developed heparin fractions.
OpenAlex reports 40 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
Using the chromogenic substrate S-2222, we have optimized and automated an amidolytic assay for heparin. The assay is based on the detection of anti-Xa activity generated by heparin in plasma. The method is reproducible (intra- and interassay CVs of 2.4 and 3.3%, respectively) and reliable in antithrombin III-deficient plasma. Results of this assay, obtained for plasma samples from patients and volunteers treated with heparin, correlate well (r = 0.899) with those of the test for activated partial thromboplastin time. Upon administration of a low-Mr heparinoid (Org 10172) and heparin fragment ( Kabi 2165), however, the activated partial thromboplastin time failed to detect anticoagulant activity, whereas the chromogenic heparin assay revealed anti-Xa activity. This automated amidolytic assay for heparin is therefore suitable not only for monitoring standard therapy with heparin but also for measuring the activity of recently developed heparin fractions.
Key concepts: Heparinoid, Heparin, Fragment (logic), Chemistry, Medicine, Chromatography, Biochemistry, Mathematics