Repeatability and Reproducibility of A-Scan Biometry Quantitative Findings
Ioannis Tsinopoulos, Konstantinos T. Tsaousis, Chrysanthos Symeonidis, Nikolaos T. Chalvatzis, Stavros A. Dimitrakos
Abstract
Ioannis Tsinopoulos, Konstantinos T. Tsaousis, Chrysanthos Symeonidis, Nikolaos T. Chalvatzis, Stavros A. Dimitrakos
Abstract
PURPOSE: To determine repeatability and reproducibility of A-scan biometry quantitative findings in order to uniformly evaluate lenticular cataract changes. MATERIALS AND METHODS: Seventeen eyes from seventeen cataract patients were examined by three (trainee ophthalmologists). Results (ratio of mean internal lens spikes height/lens anterior surface spike height) were compared using coefficient of variation (CV), repeatability coefficient (CR), and intraclass correlation coefficients (ICC). RESULTS: Intra-observer consistency was CV = 0.36, CR = 0.49, and ICC = 0.778 for the first operator; CV = 0.33, CR = 0.52, and ICC = 0.642 for the second operator; and CV = 0.32, CR = 0.53, and ICC = 0.567 for the third operator. Concerning inter-observer agreement: CV (in 6 of 7 eyes) was > 8%, CR was > 0.21, and intraclass correlation coefficient for all eyes was < 0.81. CONCLUSIONS: Regarding repeatability and reproducibility, although there is a tendency for statistical significance, variability of the results does not allow the use of the method as a complementary clinical tool for comparing results. Standardization of this procedure, in order to achieve higher test reliability, might be the aim of relevant future studies, although there are a number of points that have to be addressed.
OpenAlex reports 3 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
PURPOSE: To determine repeatability and reproducibility of A-scan biometry quantitative findings in order to uniformly evaluate lenticular cataract changes. MATERIALS AND METHODS: Seventeen eyes from seventeen cataract patients were examined by three (trainee ophthalmologists). Results (ratio of mean internal lens spikes height/lens anterior surface spike height) were compared using coefficient of variation (CV), repeatability coefficient (CR), and intraclass correlation coefficients (ICC). RESULTS: Intra-observer consistency was CV = 0.36, CR = 0.49, and ICC = 0.778 for the first operator; CV = 0.33, CR = 0.52, and ICC = 0.642 for the second operator; and CV = 0.32, CR = 0.53, and ICC = 0.567 for the third operator. Concerning inter-observer agreement: CV (in 6 of 7 eyes) was > 8%, CR was > 0.21, and intraclass correlation coefficient for all eyes was < 0.81. CONCLUSIONS: Regarding repeatability and reproducibility, although there is a tendency for statistical significance, variability of the results does not allow the use of the method as a complementary clinical tool for comparing results. Standardization of this procedure, in order to achieve higher test reliability, might be the aim of relevant future studies, although there are a number of points that have to be addressed.
Key concepts: Repeatability, Intraclass correlation, Reproducibility, Coefficient of variation, Reliability (semiconductor), Medicine, Mathematics, Ophthalmology