Respiratory mechanics of horses measured by conventional and forced oscillation techniques
Simon S Young, David B. Tesarowski
Abstract
Simon S Young, David B. Tesarowski
Abstract
Respiratory mechanics were compared using conventional and forced oscillation techniques in six conscious horses and a mechanical model of the equine respiratory system. The parameters calculated from conventional airflow and esophageal pressure measurements were pulmonary resistance and dynamic compliance. The impedance of the respiratory system was measured at 1, 2, and 3 Hz with the forced oscillation technique, and respiratory system resistance, compliance, inertance, and resonant frequency were calculated. Pulmonary resistance was 1.0 +/- 0.3 cmH2O.l-1.s, and pulmonary dynamic compliance was 2.4 +/- 0.6 l/cmH2O. With the use of the forced oscillation system, respiratory resistance was 1.61 +/- 0.50 cmH2O.l-1.s at 1 Hz, compliance was 0.195 +/- 0.075 l/cmH2O, inertance was 0.026 +/- 0.0095 cmH2O.l-1.s2, and resonant frequency was 2.40 +/- 0.25 Hz. Data collected from a model of the respiratory system showed a close correlation between resistance and compliance measured with the two systems. This study demonstrates that the forced oscillation technique is a useful method for noninvasive measurement of respiratory mechanics in horses.
OpenAlex reports 40 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
Respiratory mechanics were compared using conventional and forced oscillation techniques in six conscious horses and a mechanical model of the equine respiratory system. The parameters calculated from conventional airflow and esophageal pressure measurements were pulmonary resistance and dynamic compliance. The impedance of the respiratory system was measured at 1, 2, and 3 Hz with the forced oscillation technique, and respiratory system resistance, compliance, inertance, and resonant frequency were calculated. Pulmonary resistance was 1.0 +/- 0.3 cmH2O.l-1.s, and pulmonary dynamic compliance was 2.4 +/- 0.6 l/cmH2O. With the use of the forced oscillation system, respiratory resistance was 1.61 +/- 0.50 cmH2O.l-1.s at 1 Hz, compliance was 0.195 +/- 0.075 l/cmH2O, inertance was 0.026 +/- 0.0095 cmH2O.l-1.s2, and resonant frequency was 2.40 +/- 0.25 Hz. Data collected from a model of the respiratory system showed a close correlation between resistance and compliance measured with the two systems. This study demonstrates that the forced oscillation technique is a useful method for noninvasive measurement of respiratory mechanics in horses.
Key concepts: Inertance, Forced oscillation, Respiratory physiology, Respiratory system, Compliance (psychology), Oscillation (cell signaling), Pulmonary compliance, Airway resistance