2011•Pacing and Clinical ElectrophysiologyRequires access

Initial Single‐Center Experience of a Quadripolar Pacing Lead for Cardiac Resynchronization Therapy

Anoop Shetty, Simon G. Duckett, Julian Bostock, Debashis Roy, Matthew Ginks, Shoaib Hamid, Eric T Rosenthal, Reza Razavi, Christopher A. Rinaldi

Open publisher page 44 citations

Abstract

BACKGROUND: The Quartet model 1458Q (St. Jude Medical, Sylmar, CA, USA) lead is a quadripolar left ventricular (LV) lead with pace/sense capability from four electrodes (tip and three rings). The lead is capable of pacing in 10 different configurations rather than the three that are available in conventional bipolar pacing leads. We describe a single-center initial experience of the use of this lead in patients undergoing cardiac resynchronization therapy (CRT). METHODS: Twenty-eight patients for a CRT with cardiac defibrillator were implanted between October 2009 and May 2010 with a Quartet lead . Lead position, pacing parameters, stability, complications, and presence of phrenic nerve stimulation (PNS) data were collected at implant and predischarge. Follow-up data were collected at 15 ± 8 weeks for all patients. RESULTS: A Quartet lead was successfully implanted in 96% (27/28) of patients (age 61 ± 15 years; 82% male; ischemic etiology 50%; mean left ventricular [LV] ejection fraction 25 ± 7%; left bundle branch block 68%). PNS was seen at implant in 11 patients (41%) with at least one vector. In eight of these cases (72%), the need for lead repositioning was averted by programming LV pacing utilizing the additional vectors available with the Quartet lead. CONCLUSION: These initial data suggest that pacing with the Quartet lead is associated with a high implant success rate and stable pacing parameters acutely and at short-term follow-up. The 10 LV pacing vectors available with this lead may allow PNS and capture threshold problems to be easily overcome.

About this research paper

What this paper is about

BACKGROUND: The Quartet model 1458Q (St. Jude Medical, Sylmar, CA, USA) lead is a quadripolar left ventricular (LV) lead with pace/sense capability from four electrodes (tip and three rings). The lead is capable of pacing in 10 different configurations rather than the three that are available in conventional bipolar pacing leads. We describe a single-center initial experience of the use of this lead in patients undergoing cardiac resynchronization therapy (CRT). METHODS: Twenty-eight patients for a CRT with cardiac defibrillator were implanted between October 2009 and May 2010 with a Quartet lead . Lead position, pacing parameters, stability, complications, and presence of phrenic nerve stimulation (PNS) data were collected at implant and predischarge. Follow-up data were collected at 15 ± 8 weeks for all patients. RESULTS: A Quartet lead was successfully implanted in 96% (27/28) of patients (age 61 ± 15 years; 82% male; ischemic etiology 50%; mean left ventricular [LV] ejection fraction 25 ± 7%; left bundle branch block 68%). PNS was seen at implant in 11 patients (41%) with at least one vector. In eight of these cases (72%), the need for lead repositioning was averted by programming LV pacing utilizing the additional vectors available with the Quartet lead. CONCLUSION: These initial data suggest that pacing with the Quartet lead is associated with a high implant success rate and stable pacing parameters acutely and at short-term follow-up. The 10 LV pacing vectors available with this lead may allow PNS and capture threshold problems to be easily overcome.

Why it matters

OpenAlex reports 44 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

BACKGROUND: The Quartet model 1458Q (St. Jude Medical, Sylmar, CA, USA) lead is a quadripolar left ventricular (LV) lead with pace/sense capability from four electrodes (tip and three rings). The lead is capable of pacing in 10 different configurations rather than the three that are available in conventional bipolar pacing leads. We describe a single-center initial experience of the use of this lead in patients undergoing cardiac resynchronization therapy (CRT). METHODS: Twenty-eight patients for a CRT with cardiac defibrillator were implanted between October 2009 and May 2010 with a Quartet lead . Lead position, pacing parameters, stability, complications, and presence of phrenic nerve stimulation (PNS) data were collected at implant and predischarge. Follow-up data were collected at 15 ± 8 weeks for all patients. RESULTS: A Quartet lead was successfully implanted in 96% (27/28) of patients (age 61 ± 15 years; 82% male; ischemic etiology 50%; mean left ventricular [LV] ejection fraction 25 ± 7%; left bundle branch block 68%). PNS was seen at implant in 11 patients (41%) with at least one vector. In eight of these cases (72%), the need for lead repositioning was averted by programming LV pacing utilizing the additional vectors available with the Quartet lead. CONCLUSION: These initial data suggest that pacing with the Quartet lead is associated with a high implant success rate and stable pacing parameters acutely and at short-term follow-up. The 10 LV pacing vectors available with this lead may allow PNS and capture threshold problems to be easily overcome.

Key concepts: Medicine, Cardiac resynchronization therapy, Lead (geology), Single Center, Cardiac pacing, Center (category theory), Cardiology, Internal medicine

Related papers

Back to paper searchBrowse research topicsOriginal source
Initial Single‐Center Experience of a Quadripolar Pacing Lead for Cardiac Resynchronization Therapy — Research Paper | ScholarLens