OBJECTIVE: Selective nerve root block (SNRB) is the accepted procedure for diagnostic and therapy in lumbar radicular back pain management. The present study was to determine the accuracy of needle-tip under ultrasound guidance subsequently confirmed with fluoroscopy in patients who underwent SNRB. To date, no study comparing these two techniques has been performed. MATERIAL AND METHOD: After the IRB approval, a prospective trial was conducted to determine the accuracy of ultrasound guidance SNRB in 40 consecutive patients with lumbar radicular pain undergoing fluoroscopic guidance SNRB between January 2010 and January 2011. Firstly, needle-tip was located at the desired optimal landmark under ultrasound guidance and then subsequently fluoroscopic confirmation of needle-tip position was done. Finally, the injection was performed as usual. The primary outcome was the accuracy of needle-tip placement comparing between under ultrasound and subsequently fluoroscopic confirmation. The secondary outcome was the associated factors of the accuracy of needle-tip under ultrasound guidance. RESULTS: Seventy-eight lumbar nerve roots were injected in the patients that underwent SNRB under fluoroscopic guidance. The accuracy of needle-tip on each lumbar nerve root under ultrasound guidance with fluoroscopic confirmation ranged from 7.14% to 80.95%. Mean of the accuracy of needle-tip under ultrasound guidance comparing with subsequently fluoroscopic confirmation was 62.82% while 95% CI ranged from 51.13 to 73.50%. The age older than 65 years old was significantly associated with the poor accuracy under ultrasound guidance (p-value = 0.0095). CONCLUSIONS: To position the needle-tip under ultrasound guidance is feasible and has good safety profile. The accuracy could be achieved individually. However, because the accuracy of ultrasound guidance technique depends on the operator a steep learning curve and larger prospective clinical study is needed.

About this research paper

What this paper is about

OBJECTIVE: Selective nerve root block (SNRB) is the accepted procedure for diagnostic and therapy in lumbar radicular back pain management. The present study was to determine the accuracy of needle-tip under ultrasound guidance subsequently confirmed with fluoroscopy in patients who underwent SNRB. To date, no study comparing these two techniques has been performed. MATERIAL AND METHOD: After the IRB approval, a prospective trial was conducted to determine the accuracy of ultrasound guidance SNRB in 40 consecutive patients with lumbar radicular pain undergoing fluoroscopic guidance SNRB between January 2010 and January 2011. Firstly, needle-tip was located at the desired optimal landmark under ultrasound guidance and then subsequently fluoroscopic confirmation of needle-tip position was done. Finally, the injection was performed as usual. The primary outcome was the accuracy of needle-tip placement comparing between under ultrasound and subsequently fluoroscopic confirmation. The secondary outcome was the associated factors of the accuracy of needle-tip under ultrasound guidance. RESULTS: Seventy-eight lumbar nerve roots were injected in the patients that underwent SNRB under fluoroscopic guidance. The accuracy of needle-tip on each lumbar nerve root under ultrasound guidance with fluoroscopic confirmation ranged from 7.14% to 80.95%. Mean of the accuracy of needle-tip under ultrasound guidance comparing with subsequently fluoroscopic confirmation was 62.82% while 95% CI ranged from 51.13 to 73.50%. The age older than 65 years old was significantly associated with the poor accuracy under ultrasound guidance (p-value = 0.0095). CONCLUSIONS: To position the needle-tip under ultrasound guidance is feasible and has good safety profile. The accuracy could be achieved individually. However, because the accuracy of ultrasound guidance technique depends on the operator a steep learning curve and larger prospective clinical study is needed.

Why it matters

OpenAlex reports 14 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

OBJECTIVE: Selective nerve root block (SNRB) is the accepted procedure for diagnostic and therapy in lumbar radicular back pain management. The present study was to determine the accuracy of needle-tip under ultrasound guidance subsequently confirmed with fluoroscopy in patients who underwent SNRB. To date, no study comparing these two techniques has been performed. MATERIAL AND METHOD: After the IRB approval, a prospective trial was conducted to determine the accuracy of ultrasound guidance SNRB in 40 consecutive patients with lumbar radicular pain undergoing fluoroscopic guidance SNRB between January 2010 and January 2011. Firstly, needle-tip was located at the desired optimal landmark under ultrasound guidance and then subsequently fluoroscopic confirmation of needle-tip position was done. Finally, the injection was performed as usual. The primary outcome was the accuracy of needle-tip placement comparing between under ultrasound and subsequently fluoroscopic confirmation. The secondary outcome was the associated factors of the accuracy of needle-tip under ultrasound guidance. RESULTS: Seventy-eight lumbar nerve roots were injected in the patients that underwent SNRB under fluoroscopic guidance. The accuracy of needle-tip on each lumbar nerve root under ultrasound guidance with fluoroscopic confirmation ranged from 7.14% to 80.95%. Mean of the accuracy of needle-tip under ultrasound guidance comparing with subsequently fluoroscopic confirmation was 62.82% while 95% CI ranged from 51.13 to 73.50%. The age older than 65 years old was significantly associated with the poor accuracy under ultrasound guidance (p-value = 0.0095). CONCLUSIONS: To position the needle-tip under ultrasound guidance is feasible and has good safety profile. The accuracy could be achieved individually. However, because the accuracy of ultrasound guidance technique depends on the operator a steep learning curve and larger prospective clinical study is needed.

Key concepts: Medicine, Fluoroscopy, Ultrasound, Lumbar, Nerve root, Nerve block, Lumbar Nerve, Radicular pain