2012International Journal of Current Research and ReviewRequires access

EXPERIMENTAL ANALYSIS OF VARYING THE REFRIGERATION OIL PERCENTAGE IN COMPRESSOR ON THE PERFORMANCE OF VAPOUR COMPRESSION REFRIGERATION SYSTEM

M. Yohan, G.Kiran Kumar

Open publisher page 0 citations

Abstract

A refrigerator is a machine which attains and maintains the temperature of a space below that of surroundings by transferring heat from the space to be cooled to the surroundings with the help of a compressor. Majority of the refrigerators works on the vapor compression refrigeration system which consists of components like compressors, condensers, expansion valve and evaporator. The performance of the system depends on the performance of all the components of the system. A compressor is an important device used to raise the pressure of refrigerant to a level at which it can condense by rejecting heat to the cooling medium in the condenser. In any compressors refrigeration oil is required to prevent the friction and heat generated with in it. In general all the domestic refrigerators have hermetically sealed compressors, for these refrigerator compressors having the refrigerant R-134a and it is required good properties of refrigeration oil is required to prevent the heat generated with in the compressors. This present experimental work focus on compressor work by varying the refrigeration oil percentage on a refrigerator system capacity of 165 lts. The compressor work and performance is calculated by varying refrigeration oil percentage used in it.

About this research paper

What this paper is about

A refrigerator is a machine which attains and maintains the temperature of a space below that of surroundings by transferring heat from the space to be cooled to the surroundings with the help of a compressor. Majority of the refrigerators works on the vapor compression refrigeration system which consists of components like compressors, condensers, expansion valve and evaporator. The performance of the system depends on the performance of all the components of the system. A compressor is an important device used to raise the pressure of refrigerant to a level at which it can condense by rejecting heat to the cooling medium in the condenser. In any compressors refrigeration oil is required to prevent the friction and heat generated with in it. In general all the domestic refrigerators have hermetically sealed compressors, for these refrigerator compressors having the refrigerant R-134a and it is required good properties of refrigeration oil is required to prevent the heat generated with in the compressors. This present experimental work focus on compressor work by varying the refrigeration oil percentage on a refrigerator system capacity of 165 lts. The compressor work and performance is calculated by varying refrigeration oil percentage used in it.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

A refrigerator is a machine which attains and maintains the temperature of a space below that of surroundings by transferring heat from the space to be cooled to the surroundings with the help of a compressor. Majority of the refrigerators works on the vapor compression refrigeration system which consists of components like compressors, condensers, expansion valve and evaporator. The performance of the system depends on the performance of all the components of the system. A compressor is an important device used to raise the pressure of refrigerant to a level at which it can condense by rejecting heat to the cooling medium in the condenser. In any compressors refrigeration oil is required to prevent the friction and heat generated with in it. In general all the domestic refrigerators have hermetically sealed compressors, for these refrigerator compressors having the refrigerant R-134a and it is required good properties of refrigeration oil is required to prevent the heat generated with in the compressors. This present experimental work focus on compressor work by varying the refrigeration oil percentage on a refrigerator system capacity of 165 lts. The compressor work and performance is calculated by varying refrigeration oil percentage used in it.

Key concepts: Gas compressor, Refrigeration, Refrigerant, Thermal expansion valve, Refrigerator car, Evaporator, Condenser (optics), Vapor-compression refrigeration

Related papers

Back to paper searchBrowse research topicsOriginal source
EXPERIMENTAL ANALYSIS OF VARYING THE REFRIGERATION OIL PERCENTAGE IN COMPRESSOR ON THE PERFORMANCE OF VAPOUR COMPRESSION REFRIGERATION SYSTEM — Research Paper | ScholarLens