2012International Journal of Environmental & Analytical ChemistryRequires access

A simple flow-injection chemiluminescence method for the determination of trace pentavalent vanadium in water samples

Gai Zhang, Zuchao Meng, Hairui Ma

Open publisher page 2 citations

Abstract

A simple method for rapid determination of trace pentavalent vanadium in natural water was presented by flow-injection chemiluminescence (CL). Through water injection, luminol and potassium permanganate were eluted from the anion exchange column to generate the CL, which was enhanced in the presence of V(V). Under the optimum conditions, the increased CL intensity was linear with V(V) concentration in the range from 0.1 to 100 ng mL−1. The limit of detection was 50 pg mL−1 (3σ) and the relative standard deviation (RSD) was 2.24% (n = 5) for a 1.0 ng mL−1 V(V). At a flow rate of 2.0 mL min−1, one cycle of analysis could be performed in 0.5 min with a RSD of less than 3.0%. The proposed method was successfully applied to the determination of vanadium in natural water.

About this research paper

What this paper is about

A simple method for rapid determination of trace pentavalent vanadium in natural water was presented by flow-injection chemiluminescence (CL). Through water injection, luminol and potassium permanganate were eluted from the anion exchange column to generate the CL, which was enhanced in the presence of V(V). Under the optimum conditions, the increased CL intensity was linear with V(V) concentration in the range from 0.1 to 100 ng mL−1. The limit of detection was 50 pg mL−1 (3σ) and the relative standard deviation (RSD) was 2.24% (n = 5) for a 1.0 ng mL−1 V(V). At a flow rate of 2.0 mL min−1, one cycle of analysis could be performed in 0.5 min with a RSD of less than 3.0%. The proposed method was successfully applied to the determination of vanadium in natural water.

Why it matters

OpenAlex reports 2 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

A simple method for rapid determination of trace pentavalent vanadium in natural water was presented by flow-injection chemiluminescence (CL). Through water injection, luminol and potassium permanganate were eluted from the anion exchange column to generate the CL, which was enhanced in the presence of V(V). Under the optimum conditions, the increased CL intensity was linear with V(V) concentration in the range from 0.1 to 100 ng mL−1. The limit of detection was 50 pg mL−1 (3σ) and the relative standard deviation (RSD) was 2.24% (n = 5) for a 1.0 ng mL−1 V(V). At a flow rate of 2.0 mL min−1, one cycle of analysis could be performed in 0.5 min with a RSD of less than 3.0%. The proposed method was successfully applied to the determination of vanadium in natural water.

Key concepts: Potassium permanganate, Detection limit, Chemistry, Vanadium, Chemiluminescence, Luminol, Chromatography, Elution

Related papers

Back to paper searchBrowse research topicsOriginal source
A simple flow-injection chemiluminescence method for the determination of trace pentavalent vanadium in water samples — Research Paper | ScholarLens