2004•Journal of the American Veterinary Medical AssociationOpen access

Comparison of the standard predictive equation for calculation of resting energy expenditure with indirect calorimetry in hospitalized and healthy dogs

Elizabeth O'Toole, Craig W. Miller, BRIAN A. WILSON, Karol A. Mathews, Clive Davis, William Sears

Open full text 46 citations

Abstract

OBJECTIVE: To determine the level of clinical agreement between 2 methods for the measurement of resting energy expenditure (REE). DESIGN: Prospective case series. ANIMALS: 77 dogs. PROCEDURE: Oxygen consumption (Vo2) and CO2 production (Vco2) were measured with an open-flow indirect calorimeter in healthy (n = 10) and ill (67) dogs. Measurements were collected at 3 time periods on 2 days. The Vo2 and the Vco2 measurements were then used to calculate the REE values. RESULTS: Mean values of measured (MREE) and predicted (PREE) REEs in healthy dogs and a dog with medical illnesses or trauma were not significantly different. There was a significant difference on day 2 between the MREE and PREE in the group of dogs recovering from major surgery. More importantly, there was significant variation between the PREE and MREE on an individual-dog basis. The PREE only agreed to within +/- 20% of the MREE in 51% to 57% of the dogs. CONCLUSIONS AND CLINICAL RELEVANCE: The level of agreement between these two methods for determining the 24-hour REE was poor in individual dogs. The level of disagreement between the 2 methods indicates that these methods may not be used interchangeably in a clinical setting. Measurement of REE by use of indirect calorimetry may be the only reliable method of determining REE in an individual ill or healthy dog.

Open-access reader

About this research paper

What this paper is about

OBJECTIVE: To determine the level of clinical agreement between 2 methods for the measurement of resting energy expenditure (REE). DESIGN: Prospective case series. ANIMALS: 77 dogs. PROCEDURE: Oxygen consumption (Vo2) and CO2 production (Vco2) were measured with an open-flow indirect calorimeter in healthy (n = 10) and ill (67) dogs. Measurements were collected at 3 time periods on 2 days. The Vo2 and the Vco2 measurements were then used to calculate the REE values. RESULTS: Mean values of measured (MREE) and predicted (PREE) REEs in healthy dogs and a dog with medical illnesses or trauma were not significantly different. There was a significant difference on day 2 between the MREE and PREE in the group of dogs recovering from major surgery. More importantly, there was significant variation between the PREE and MREE on an individual-dog basis. The PREE only agreed to within +/- 20% of the MREE in 51% to 57% of the dogs. CONCLUSIONS AND CLINICAL RELEVANCE: The level of agreement between these two methods for determining the 24-hour REE was poor in individual dogs. The level of disagreement between the 2 methods indicates that these methods may not be used interchangeably in a clinical setting. Measurement of REE by use of indirect calorimetry may be the only reliable method of determining REE in an individual ill or healthy dog.

Why it matters

OpenAlex reports 46 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

OBJECTIVE: To determine the level of clinical agreement between 2 methods for the measurement of resting energy expenditure (REE). DESIGN: Prospective case series. ANIMALS: 77 dogs. PROCEDURE: Oxygen consumption (Vo2) and CO2 production (Vco2) were measured with an open-flow indirect calorimeter in healthy (n = 10) and ill (67) dogs. Measurements were collected at 3 time periods on 2 days. The Vo2 and the Vco2 measurements were then used to calculate the REE values. RESULTS: Mean values of measured (MREE) and predicted (PREE) REEs in healthy dogs and a dog with medical illnesses or trauma were not significantly different. There was a significant difference on day 2 between the MREE and PREE in the group of dogs recovering from major surgery. More importantly, there was significant variation between the PREE and MREE on an individual-dog basis. The PREE only agreed to within +/- 20% of the MREE in 51% to 57% of the dogs. CONCLUSIONS AND CLINICAL RELEVANCE: The level of agreement between these two methods for determining the 24-hour REE was poor in individual dogs. The level of disagreement between the 2 methods indicates that these methods may not be used interchangeably in a clinical setting. Measurement of REE by use of indirect calorimetry may be the only reliable method of determining REE in an individual ill or healthy dog.

Key concepts: Resting energy expenditure, Energy expenditure, Medicine, Limits of agreement, Clinical significance, Calorimetry, Nuclear medicine, Animal science

Related papers

Back to paper searchBrowse research topicsOriginal source
Comparison of the standard predictive equation for calculation of resting energy expenditure with indirect calorimetry in hospitalized and healthy dogs — Research Paper | ScholarLens