1984Clinical Chemistry and Laboratory Medicine (CCLM)Open access

Serum Amylase and Isoamylase Assay on the Hitachi 705 Automatic Clinical Chemical Analyzer

Markku Parviainen, Timo Koivula, Hannu Jokela

Open full text 3 citations

Abstract

The automated continuous alpha-amylase assay using p-nitrophenyl-alpha-D-maltoheptaoside (Boehringer Mannheim) as substrate on the Hitachi 705 clinical chemical analyzer, was compared with the Phadebas Kinetic Amylase Assay (Pharmacia Diagnostics) on the Hitachi 705. The two methods showed good correlation. The precision varied from 1.0 to 2.5% (CV) within-day and from 1.1 to 5.6% (CV) day-to-day. The substrate, p-nitrophenyl-alpha-D-maltoheptaoside, was also applied to an automated isoamylase assay. The amylase inhibitor from wheat was used to determine the ratio of pancreatic and salivary amylase activities of serum. About 80% of salivary type amylase was inhibited up to an activity level of 1000 U/l, while inhibition of pancreatic type amylase activity was only 10-15%. Ratios of pancreatic to salivary amylase from 0.1 to 10 can be evaluated in serum with wheat inhibitor. The precision of the isoamylase determination by the Boehringer amylase method was acceptable.

Open-access reader

About this research paper

What this paper is about

The automated continuous alpha-amylase assay using p-nitrophenyl-alpha-D-maltoheptaoside (Boehringer Mannheim) as substrate on the Hitachi 705 clinical chemical analyzer, was compared with the Phadebas Kinetic Amylase Assay (Pharmacia Diagnostics) on the Hitachi 705. The two methods showed good correlation. The precision varied from 1.0 to 2.5% (CV) within-day and from 1.1 to 5.6% (CV) day-to-day. The substrate, p-nitrophenyl-alpha-D-maltoheptaoside, was also applied to an automated isoamylase assay. The amylase inhibitor from wheat was used to determine the ratio of pancreatic and salivary amylase activities of serum. About 80% of salivary type amylase was inhibited up to an activity level of 1000 U/l, while inhibition of pancreatic type amylase activity was only 10-15%. Ratios of pancreatic to salivary amylase from 0.1 to 10 can be evaluated in serum with wheat inhibitor. The precision of the isoamylase determination by the Boehringer amylase method was acceptable.

Why it matters

OpenAlex reports 3 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The automated continuous alpha-amylase assay using p-nitrophenyl-alpha-D-maltoheptaoside (Boehringer Mannheim) as substrate on the Hitachi 705 clinical chemical analyzer, was compared with the Phadebas Kinetic Amylase Assay (Pharmacia Diagnostics) on the Hitachi 705. The two methods showed good correlation. The precision varied from 1.0 to 2.5% (CV) within-day and from 1.1 to 5.6% (CV) day-to-day. The substrate, p-nitrophenyl-alpha-D-maltoheptaoside, was also applied to an automated isoamylase assay. The amylase inhibitor from wheat was used to determine the ratio of pancreatic and salivary amylase activities of serum. About 80% of salivary type amylase was inhibited up to an activity level of 1000 U/l, while inhibition of pancreatic type amylase activity was only 10-15%. Ratios of pancreatic to salivary amylase from 0.1 to 10 can be evaluated in serum with wheat inhibitor. The precision of the isoamylase determination by the Boehringer amylase method was acceptable.

Key concepts: Isoamylase, Amylase, Chemistry, Chromatography, Substrate (aquarium), Alpha-amylase, Enzyme, Internal medicine

Related papers

Back to paper searchBrowse research topicsOriginal source
Serum Amylase and Isoamylase Assay on the Hitachi 705 Automatic Clinical Chemical Analyzer — Research Paper | ScholarLens