2008Unpublished venueRequires access

Study of Pulse Wave Velocity Noninvasive Detecting Instrument Based on Radial Artery and Finger Photoplethysmography Pulse Wave

Yang Lin, Song Zhang, Yang Yimin

Open publisher page 15 citations

Abstract

A radial artery and finger photoplethysmography (PPG) pulse wave velocity (PWV) noninvasive detecting instrument is designed. This instrument detects radial artery pulse wave and finger PPG pulse wave synchronously, and then radial-finger pulse wave velocity (PWVrf) is computed. The hardware adopts two separate circuits to reduce interference between the coinstantaneous radial artery pulse wave detection and finger PPG pulse wave detection. Moreover, the software can store detection results for dynamic analysis. The instrument has the advantage of convenience. It is noninvasive and has good clinical value in the detection of PWV.

About this research paper

What this paper is about

A radial artery and finger photoplethysmography (PPG) pulse wave velocity (PWV) noninvasive detecting instrument is designed. This instrument detects radial artery pulse wave and finger PPG pulse wave synchronously, and then radial-finger pulse wave velocity (PWVrf) is computed. The hardware adopts two separate circuits to reduce interference between the coinstantaneous radial artery pulse wave detection and finger PPG pulse wave detection. Moreover, the software can store detection results for dynamic analysis. The instrument has the advantage of convenience. It is noninvasive and has good clinical value in the detection of PWV.

Why it matters

OpenAlex reports 15 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

A radial artery and finger photoplethysmography (PPG) pulse wave velocity (PWV) noninvasive detecting instrument is designed. This instrument detects radial artery pulse wave and finger PPG pulse wave synchronously, and then radial-finger pulse wave velocity (PWVrf) is computed. The hardware adopts two separate circuits to reduce interference between the coinstantaneous radial artery pulse wave detection and finger PPG pulse wave detection. Moreover, the software can store detection results for dynamic analysis. The instrument has the advantage of convenience. It is noninvasive and has good clinical value in the detection of PWV.

Key concepts: Photoplethysmogram, Pulse wave velocity, Radial artery, Pulse (music), Pulse wave, Pulse Wave Analysis, Interference (communication), Acoustics

Related papers

Back to paper searchBrowse research topicsOriginal source
Study of Pulse Wave Velocity Noninvasive Detecting Instrument Based on Radial Artery and Finger Photoplethysmography Pulse Wave — Research Paper | ScholarLens