Generating electrospray from solutions predeposited on a copper wire

Chi-Ming Hong, Chwan-Tzong Lee, Yu-Ming Lee, Chih-Pin Kuo, Cheng‐Hui Yuan, Jentaie Shiea

Open publisher page 74 citations

Abstract

This study presents a novel direct probe (DP) to perform electrospray ionization (ESI). The probe is constructed simply from a thin copper ring connected to a high voltage power supply, and a capillary and syringe pump are unnecessary. Approximately one microliter of the sample solution is applied directly onto the copper ring by a micropipette. Electrospray from the solution on the copper ring is induced by surface deformation by deflecting a droplet from the copper ring. The mass spectra of proteins obtained by DP–ESI are exactly the same as those from conventional ESI sources through a capillary needle. The time deemed necessary to complete an analysis is approximately 2 minutes, and sample switching is immediate. The signals of the analyte can last from 45 seconds to more than 10 minutes depending on probe design. Three different types of probes used to retain more sample solution on the probe during electrospray were designed and constructed. Moreover, cleaning the probe between different sample analysis is easy. Since a capillary is not used for sample transportation, presence of the particles in the sample solution does not interfere with the electrospray process by capillary blockage. Copyright © 1999 John Wiley & Sons, Ltd.

About this research paper

What this paper is about

This study presents a novel direct probe (DP) to perform electrospray ionization (ESI). The probe is constructed simply from a thin copper ring connected to a high voltage power supply, and a capillary and syringe pump are unnecessary. Approximately one microliter of the sample solution is applied directly onto the copper ring by a micropipette. Electrospray from the solution on the copper ring is induced by surface deformation by deflecting a droplet from the copper ring. The mass spectra of proteins obtained by DP–ESI are exactly the same as those from conventional ESI sources through a capillary needle. The time deemed necessary to complete an analysis is approximately 2 minutes, and sample switching is immediate. The signals of the analyte can last from 45 seconds to more than 10 minutes depending on probe design. Three different types of probes used to retain more sample solution on the probe during electrospray were designed and constructed. Moreover, cleaning the probe between different sample analysis is easy. Since a capillary is not used for sample transportation, presence of the particles in the sample solution does not interfere with the electrospray process by capillary blockage. Copyright © 1999 John Wiley & Sons, Ltd.

Why it matters

OpenAlex reports 74 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

This study presents a novel direct probe (DP) to perform electrospray ionization (ESI). The probe is constructed simply from a thin copper ring connected to a high voltage power supply, and a capillary and syringe pump are unnecessary. Approximately one microliter of the sample solution is applied directly onto the copper ring by a micropipette. Electrospray from the solution on the copper ring is induced by surface deformation by deflecting a droplet from the copper ring. The mass spectra of proteins obtained by DP–ESI are exactly the same as those from conventional ESI sources through a capillary needle. The time deemed necessary to complete an analysis is approximately 2 minutes, and sample switching is immediate. The signals of the analyte can last from 45 seconds to more than 10 minutes depending on probe design. Three different types of probes used to retain more sample solution on the probe during electrospray were designed and constructed. Moreover, cleaning the probe between different sample analysis is easy. Since a capillary is not used for sample transportation, presence of the particles in the sample solution does not interfere with the electrospray process by capillary blockage. Copyright © 1999 John Wiley & Sons, Ltd.

Key concepts: Electrospray, Chemistry, Copper, Capillary action, Analyte, Electrospray ionization, Extractive electrospray ionization, Analytical Chemistry (journal)

Related papers

Back to paper searchBrowse research topicsOriginal source
Generating electrospray from solutions predeposited on a copper wire — Research Paper | ScholarLens