2000Unpublished venueRequires access

Determining the discharge coefficient of a spool valve

E. N. Viall, Qin Zhang

Open publisher page 17 citations

Abstract

Various mathematical models and experimental methods have been developed for finding the effective orifice area in spool valves. The orifice equation for turbulent flow is often applied to spool valves to determine the volumetric flow rate of the fluid passing through the spool valve. This equation involves the discharge coefficient, C/sub d/, in calculating the effective area. The discharge coefficient has been to shown to vary with the spool position and Reynolds number. For small displacements of the spool, mathematical models have been developed to determine the discharge coefficient. However, for larger displacements, C/sub d/ is determined with greater uncertainty. An experimental procedure has been proposed to find the discharge coefficient of a spool valve as a function of the spool displacement and pressure drop across the orifice. This procedure involves measuring the flow rate through the valve at certain spool positions for stationary spool positions or time-varying spool positions. The physical area of the orifice created by the moving spool can be calculated from physical dimensions. Finally, pressure drop across the valve is measured while measuring fluid temperature. Flow rate, orifice area, pressure drop, and temperature are used to calculate the discharge coefficient from the orifice equation for turbulent flow.

About this research paper

What this paper is about

Various mathematical models and experimental methods have been developed for finding the effective orifice area in spool valves. The orifice equation for turbulent flow is often applied to spool valves to determine the volumetric flow rate of the fluid passing through the spool valve. This equation involves the discharge coefficient, C/sub d/, in calculating the effective area. The discharge coefficient has been to shown to vary with the spool position and Reynolds number. For small displacements of the spool, mathematical models have been developed to determine the discharge coefficient. However, for larger displacements, C/sub d/ is determined with greater uncertainty. An experimental procedure has been proposed to find the discharge coefficient of a spool valve as a function of the spool displacement and pressure drop across the orifice. This procedure involves measuring the flow rate through the valve at certain spool positions for stationary spool positions or time-varying spool positions. The physical area of the orifice created by the moving spool can be calculated from physical dimensions. Finally, pressure drop across the valve is measured while measuring fluid temperature. Flow rate, orifice area, pressure drop, and temperature are used to calculate the discharge coefficient from the orifice equation for turbulent flow.

Why it matters

OpenAlex reports 17 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Various mathematical models and experimental methods have been developed for finding the effective orifice area in spool valves. The orifice equation for turbulent flow is often applied to spool valves to determine the volumetric flow rate of the fluid passing through the spool valve. This equation involves the discharge coefficient, C/sub d/, in calculating the effective area. The discharge coefficient has been to shown to vary with the spool position and Reynolds number. For small displacements of the spool, mathematical models have been developed to determine the discharge coefficient. However, for larger displacements, C/sub d/ is determined with greater uncertainty. An experimental procedure has been proposed to find the discharge coefficient of a spool valve as a function of the spool displacement and pressure drop across the orifice. This procedure involves measuring the flow rate through the valve at certain spool positions for stationary spool positions or time-varying spool positions. The physical area of the orifice created by the moving spool can be calculated from physical dimensions. Finally, pressure drop across the valve is measured while measuring fluid temperature. Flow rate, orifice area, pressure drop, and temperature are used to calculate the discharge coefficient from the orifice equation for turbulent flow.

Key concepts: Body orifice, Flow coefficient, Discharge coefficient, Mechanics, Pressure drop, Orifice plate, Turbulence, Reynolds number