Analysis and performance assessment of the active frequency drift method of islanding prevention
Michael E. Ropp, Miroslav M. Begovic, Ajeet Rohatgi
Abstract
Michael E. Ropp, Miroslav M. Begovic, Ajeet Rohatgi
Abstract
Islanding of photovoltaic (PV) systems can cause a variety of problems and must be prevented. However, if the real and reactive powers of the load and PV system are closely matched, islanding detection by passive methods becomes difficult. Also, most active methods lose effectiveness when there are several PV systems feeding the same island. The active frequency drift method (AFD), also called the frequency bias method, enables islanding detection by forcing the frequency of the voltage in the island to drift up or down. In this paper, AFD is studied analytically, using the describing function analysis technique, and by simulation, using MATLAB. It is shown that AFD has a nondetection zone (NDZ) in which it fails to detect islanding, and that this NDZ includes a range of unity-power-factor loads. Finally, the paper describes a novel method using positive feedback which significantly shrinks the size of the AFD NDZ.
OpenAlex reports 397 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
Islanding of photovoltaic (PV) systems can cause a variety of problems and must be prevented. However, if the real and reactive powers of the load and PV system are closely matched, islanding detection by passive methods becomes difficult. Also, most active methods lose effectiveness when there are several PV systems feeding the same island. The active frequency drift method (AFD), also called the frequency bias method, enables islanding detection by forcing the frequency of the voltage in the island to drift up or down. In this paper, AFD is studied analytically, using the describing function analysis technique, and by simulation, using MATLAB. It is shown that AFD has a nondetection zone (NDZ) in which it fails to detect islanding, and that this NDZ includes a range of unity-power-factor loads. Finally, the paper describes a novel method using positive feedback which significantly shrinks the size of the AFD NDZ.
Key concepts: Islanding, Frequency drift, Photovoltaic system, AC power, Control theory (sociology), MATLAB, Voltage, Automatic frequency control