1957Journal of the Optical Society of AmericaRequires access

Absolute Radiometry Based on a Change in Electrical Resistance

Marion Eppley, A. R. Karoli

Open publisher page 12 citations

Abstract

A blackbody and an electrical method of absolute radiometry employing direct current instruments for the measurement of current and resistance are described. The blackbody, designed for performance near 1000°C, is an electrically heated tubular furnace containing an oxidized steel chamber as the radiating source. The radiometer consists, essentially, of a coil of platinum wire wound spirally and bifilar-wise on a blackened, thin, silver disk from which it is electrically insulated but in good thermal contact. The change in resistance of the coil is a measure of the radiation absorbed by the coated disk. By heating the coil electrically, the energy required to produce this change is readily calculated; thus, the deviation of the radiant energy of the source from the corresponding computed perfect blackbody radiation can be determined. This method indicated that the radiant flux emitted by the above source is within 1% of that from such an ideal blackbody at a temperature between 800°C and 1100°C. Included is a description of the apparatus used in the assemblage, as well as of the procedure followed in obtaining data, with a discussion of the probable sources of error.

About this research paper

What this paper is about

A blackbody and an electrical method of absolute radiometry employing direct current instruments for the measurement of current and resistance are described. The blackbody, designed for performance near 1000°C, is an electrically heated tubular furnace containing an oxidized steel chamber as the radiating source. The radiometer consists, essentially, of a coil of platinum wire wound spirally and bifilar-wise on a blackened, thin, silver disk from which it is electrically insulated but in good thermal contact. The change in resistance of the coil is a measure of the radiation absorbed by the coated disk. By heating the coil electrically, the energy required to produce this change is readily calculated; thus, the deviation of the radiant energy of the source from the corresponding computed perfect blackbody radiation can be determined. This method indicated that the radiant flux emitted by the above source is within 1% of that from such an ideal blackbody at a temperature between 800°C and 1100°C. Included is a description of the apparatus used in the assemblage, as well as of the procedure followed in obtaining data, with a discussion of the probable sources of error.

Why it matters

OpenAlex reports 12 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

A blackbody and an electrical method of absolute radiometry employing direct current instruments for the measurement of current and resistance are described. The blackbody, designed for performance near 1000°C, is an electrically heated tubular furnace containing an oxidized steel chamber as the radiating source. The radiometer consists, essentially, of a coil of platinum wire wound spirally and bifilar-wise on a blackened, thin, silver disk from which it is electrically insulated but in good thermal contact. The change in resistance of the coil is a measure of the radiation absorbed by the coated disk. By heating the coil electrically, the energy required to produce this change is readily calculated; thus, the deviation of the radiant energy of the source from the corresponding computed perfect blackbody radiation can be determined. This method indicated that the radiant flux emitted by the above source is within 1% of that from such an ideal blackbody at a temperature between 800°C and 1100°C. Included is a description of the apparatus used in the assemblage, as well as of the procedure followed in obtaining data, with a discussion of the probable sources of error.

Key concepts: Black-body radiation, Radiant energy, Radiometry, Optics, Radiant flux, Radiometer, Electromagnetic coil, Bifilar coil

Related papers

Back to paper searchBrowse research topicsOriginal source
Absolute Radiometry Based on a Change in Electrical Resistance — Research Paper | ScholarLens