2008American Journal of Applied SciencesRequires access

Determination of Ibuprofen and Paracetamol in Binary Mixture Using Chemometric-Assisted Spectrophotometric Methods

Wаfаа S. Hаssаn

Open publisher page 43 citations

Abstract

Three methods are presented for simultaneous determination of ibuprofen and paracetamol without previous separation. The first method depends on first derivative UV spectrophotometry, with zero-crossing measurement. The first derivative amplitudes at 230 and 290 nm were selected for the assay of ibuprofen and paracetamol, respectively. The second method depends on first derivative of the ratio-spectra by measurements of the amplitudes at 280 and 290 nm for ibuprofen and paracetamol, respectively. Calibration graphs were established in the range of 5-100 and 10-100 µg mL-1 for ibuprofen and paracetamol, respectively. The third method is the use of multivariate spectrophotometric calibration for the simultaneous determination of the analyzed mixture. The resolution of the studied binary mixture has been accomplished by using partial least squares (PLS) regression analysis. Although the components show an important degree of spectral overlap, they have been simultaneously determined with high accuracy, with no interference from pharmaceutical dosage form excipients. A comparison is presented with the related multivariate method of classical least squares (CLS) analysis, which is shown to yield less reliable results due to severe spectra overlap presented by the studied compounds. All of the proposed methods have been extensively validated. These methods allow a number of cost and time saving benefits. The described methods can be readily utilized for analysis of pharmaceutical formulations. There was no significant difference between the performance of all of the proposed methods regarding the mean values and standard deviations.

About this research paper

What this paper is about

Three methods are presented for simultaneous determination of ibuprofen and paracetamol without previous separation. The first method depends on first derivative UV spectrophotometry, with zero-crossing measurement. The first derivative amplitudes at 230 and 290 nm were selected for the assay of ibuprofen and paracetamol, respectively. The second method depends on first derivative of the ratio-spectra by measurements of the amplitudes at 280 and 290 nm for ibuprofen and paracetamol, respectively. Calibration graphs were established in the range of 5-100 and 10-100 µg mL-1 for ibuprofen and paracetamol, respectively. The third method is the use of multivariate spectrophotometric calibration for the simultaneous determination of the analyzed mixture. The resolution of the studied binary mixture has been accomplished by using partial least squares (PLS) regression analysis. Although the components show an important degree of spectral overlap, they have been simultaneously determined with high accuracy, with no interference from pharmaceutical dosage form excipients. A comparison is presented with the related multivariate method of classical least squares (CLS) analysis, which is shown to yield less reliable results due to severe spectra overlap presented by the studied compounds. All of the proposed methods have been extensively validated. These methods allow a number of cost and time saving benefits. The described methods can be readily utilized for analysis of pharmaceutical formulations. There was no significant difference between the performance of all of the proposed methods regarding the mean values and standard deviations.

Why it matters

OpenAlex reports 43 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Three methods are presented for simultaneous determination of ibuprofen and paracetamol without previous separation. The first method depends on first derivative UV spectrophotometry, with zero-crossing measurement. The first derivative amplitudes at 230 and 290 nm were selected for the assay of ibuprofen and paracetamol, respectively. The second method depends on first derivative of the ratio-spectra by measurements of the amplitudes at 280 and 290 nm for ibuprofen and paracetamol, respectively. Calibration graphs were established in the range of 5-100 and 10-100 µg mL-1 for ibuprofen and paracetamol, respectively. The third method is the use of multivariate spectrophotometric calibration for the simultaneous determination of the analyzed mixture. The resolution of the studied binary mixture has been accomplished by using partial least squares (PLS) regression analysis. Although the components show an important degree of spectral overlap, they have been simultaneously determined with high accuracy, with no interference from pharmaceutical dosage form excipients. A comparison is presented with the related multivariate method of classical least squares (CLS) analysis, which is shown to yield less reliable results due to severe spectra overlap presented by the studied compounds. All of the proposed methods have been extensively validated. These methods allow a number of cost and time saving benefits. The described methods can be readily utilized for analysis of pharmaceutical formulations. There was no significant difference between the performance of all of the proposed methods regarding the mean values and standard deviations.

Key concepts: Ibuprofen, Chromatography, Binary number, Chemometrics, Chemistry, Mathematics, Medicine, Pharmacology

Related papers

Back to paper searchBrowse research topicsOriginal source
Determination of Ibuprofen and Paracetamol in Binary Mixture Using Chemometric-Assisted Spectrophotometric Methods — Research Paper | ScholarLens