2012•Respiratory CareRequires access

Bronchodilator Response in Patients With Normal Baseline Spirometry

Matthew J. Hegewald, Ryan G Townsend, Jaron T Abbott, Robert O. Crapo

Open publisher page 28 citations

Abstract

BACKGROUND: Spirometry before and after bronchodilator is performed to assess air flow-limitation reversibility. In patients with normal baseline spirometry the frequency of a positive bronchodilator response, as defined by American Thoracic Society/European Respiratory Society criteria, has not been described. METHODS: We retrospectively analyzed adult patients tested in 2 academic pulmonary function testing laboratories over a 7-year period, with specific attention to patients who underwent bronchodilator testing after a normal baseline spirometry (FEV(1), FVC, and FEV(1)/FVC within normal limits). The frequency of a positive response to bronchodilator, defined as a 12% and 200 mL increase in either FEV(1) or FVC, was calculated and associated with demographic factors. RESULTS: Of the 1,394 patients with normal spirometry who were administered bronchodilator, 43 (3.1%) had a positive response. The percent of patients responding to bronchodilator were grouped according to pre-bronchodilator FEV(1): > lower limit of normal to 90% of predicted = 6.9%, 90-100% of predicted = 1.9%, and > 100% of predicted = 0%. An FEV(1)/FVC in the lowest 2 quartiles was associated with a higher frequency of bronchodilator response. Older patients were more likely to respond to bronchodilator, but no other demographic factors were associated with a positive bronchodilator response. CONCLUSIONS: In our study population the frequency of a positive bronchodilator response in patients with normal baseline spirometry is 3.1%. None of the patients with a pre-bronchodilator FEV(1) > 100% of predicted and only 1.9% of patients with an FEV(1) between 90% and 100% of predicted responded. Bronchodilator testing can be omitted in patients with normal spirometry and an FEV(1) above 90% of predicted, as they have a low probability of a positive response.

About this research paper

What this paper is about

BACKGROUND: Spirometry before and after bronchodilator is performed to assess air flow-limitation reversibility. In patients with normal baseline spirometry the frequency of a positive bronchodilator response, as defined by American Thoracic Society/European Respiratory Society criteria, has not been described. METHODS: We retrospectively analyzed adult patients tested in 2 academic pulmonary function testing laboratories over a 7-year period, with specific attention to patients who underwent bronchodilator testing after a normal baseline spirometry (FEV(1), FVC, and FEV(1)/FVC within normal limits). The frequency of a positive response to bronchodilator, defined as a 12% and 200 mL increase in either FEV(1) or FVC, was calculated and associated with demographic factors. RESULTS: Of the 1,394 patients with normal spirometry who were administered bronchodilator, 43 (3.1%) had a positive response. The percent of patients responding to bronchodilator were grouped according to pre-bronchodilator FEV(1): > lower limit of normal to 90% of predicted = 6.9%, 90-100% of predicted = 1.9%, and > 100% of predicted = 0%. An FEV(1)/FVC in the lowest 2 quartiles was associated with a higher frequency of bronchodilator response. Older patients were more likely to respond to bronchodilator, but no other demographic factors were associated with a positive bronchodilator response. CONCLUSIONS: In our study population the frequency of a positive bronchodilator response in patients with normal baseline spirometry is 3.1%. None of the patients with a pre-bronchodilator FEV(1) > 100% of predicted and only 1.9% of patients with an FEV(1) between 90% and 100% of predicted responded. Bronchodilator testing can be omitted in patients with normal spirometry and an FEV(1) above 90% of predicted, as they have a low probability of a positive response.

Why it matters

OpenAlex reports 28 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

BACKGROUND: Spirometry before and after bronchodilator is performed to assess air flow-limitation reversibility. In patients with normal baseline spirometry the frequency of a positive bronchodilator response, as defined by American Thoracic Society/European Respiratory Society criteria, has not been described. METHODS: We retrospectively analyzed adult patients tested in 2 academic pulmonary function testing laboratories over a 7-year period, with specific attention to patients who underwent bronchodilator testing after a normal baseline spirometry (FEV(1), FVC, and FEV(1)/FVC within normal limits). The frequency of a positive response to bronchodilator, defined as a 12% and 200 mL increase in either FEV(1) or FVC, was calculated and associated with demographic factors. RESULTS: Of the 1,394 patients with normal spirometry who were administered bronchodilator, 43 (3.1%) had a positive response. The percent of patients responding to bronchodilator were grouped according to pre-bronchodilator FEV(1): > lower limit of normal to 90% of predicted = 6.9%, 90-100% of predicted = 1.9%, and > 100% of predicted = 0%. An FEV(1)/FVC in the lowest 2 quartiles was associated with a higher frequency of bronchodilator response. Older patients were more likely to respond to bronchodilator, but no other demographic factors were associated with a positive bronchodilator response. CONCLUSIONS: In our study population the frequency of a positive bronchodilator response in patients with normal baseline spirometry is 3.1%. None of the patients with a pre-bronchodilator FEV(1) > 100% of predicted and only 1.9% of patients with an FEV(1) between 90% and 100% of predicted responded. Bronchodilator testing can be omitted in patients with normal spirometry and an FEV(1) above 90% of predicted, as they have a low probability of a positive response.

Key concepts: Bronchodilator, Spirometry, Medicine, Bronchodilator Agents, Anesthesia, Cardiology, Pulmonary function testing, Internal medicine

Related papers

Back to paper searchBrowse research topicsOriginal source
Bronchodilator Response in Patients With Normal Baseline Spirometry — Research Paper | ScholarLens