2014International Journal of Laboratory HematologyRequires access

Diagnosis of Glanzmann thrombasthenia by whole blood impedance analyzer ( MEA ) vs. light transmission aggregometry

Abdulmajeed Albanyan, A. Al‐Musa, Randa Alnounou, H. Al Zahrani, Rasheed Nasr, Abdallah Al-Jefri, Mostafa Saleh, Abdul Malik, H. Masmali, Tarek Owaidah

Open publisher page 33 citations

Abstract

BACKGROUND: Glanzmann thrombasthenia (GT) is a rare inherited platelet disorder that is characterized by spontaneous or postprocedural bleeding. The diagnosis of GT depends on identifying the dysfunction of the platelets. AIM: The aim of this study was to compare a whole blood impedance Multiplate analyzer (MEA) with the standard method, light transmission aggregometry (LTA) in diagnosis of GT. METHODS: Fifteen patients with GT were assessed on MEA and LTA using arachidonic acid (ASPI: 15 mm), (TRAP: 1 mm), collagen (100 μg/mL), ADP (0.2 mm), and ristocetin (Risto: 10 mg/mL). Whole blood samples were collected in sodium citrate and hirudin vacuum, blood collection tubes and tested within 4 h. Platelet-rich plasma was used for LTA using platelet agonists (ristocetin 1.5 mg/mL) (arachidonic acid 0.5 mg/mL) (ADP 2.5 mg/mL) and (collagen 1 mg/mL). RESULTS: The platelet count and PFA-100 results were (average and SD) 319 ± 93 × 10(9) L and 252 ± 34 s, respectively. Flow cytometry analysis showed that all samples are positive for CD42a and CD42b, whereas 9/15 samples were negative for CD61 and CD41. The other six patients had either partial or full expression of CD61/CD41. Aggregation analysis using both methods showed that all samples had no aggregation response to any of the agonists used apart from six samples which, using only the MEA, showed minimal aggregation in response to collagen (average = 14.3 ± 7 μg, which may suggest ability to detect qualitative abnormality of GPIIb/IIIa). CONCLUSION: These results suggest that the MEA is sensitive for the detection of Glanzmann thrombasthenia. Furthermore, MEA may also be able to differentiate between the subtypes of Glanzmann thrombasthenia.

About this research paper

What this paper is about

BACKGROUND: Glanzmann thrombasthenia (GT) is a rare inherited platelet disorder that is characterized by spontaneous or postprocedural bleeding. The diagnosis of GT depends on identifying the dysfunction of the platelets. AIM: The aim of this study was to compare a whole blood impedance Multiplate analyzer (MEA) with the standard method, light transmission aggregometry (LTA) in diagnosis of GT. METHODS: Fifteen patients with GT were assessed on MEA and LTA using arachidonic acid (ASPI: 15 mm), (TRAP: 1 mm), collagen (100 μg/mL), ADP (0.2 mm), and ristocetin (Risto: 10 mg/mL). Whole blood samples were collected in sodium citrate and hirudin vacuum, blood collection tubes and tested within 4 h. Platelet-rich plasma was used for LTA using platelet agonists (ristocetin 1.5 mg/mL) (arachidonic acid 0.5 mg/mL) (ADP 2.5 mg/mL) and (collagen 1 mg/mL). RESULTS: The platelet count and PFA-100 results were (average and SD) 319 ± 93 × 10(9) L and 252 ± 34 s, respectively. Flow cytometry analysis showed that all samples are positive for CD42a and CD42b, whereas 9/15 samples were negative for CD61 and CD41. The other six patients had either partial or full expression of CD61/CD41. Aggregation analysis using both methods showed that all samples had no aggregation response to any of the agonists used apart from six samples which, using only the MEA, showed minimal aggregation in response to collagen (average = 14.3 ± 7 μg, which may suggest ability to detect qualitative abnormality of GPIIb/IIIa). CONCLUSION: These results suggest that the MEA is sensitive for the detection of Glanzmann thrombasthenia. Furthermore, MEA may also be able to differentiate between the subtypes of Glanzmann thrombasthenia.

Why it matters

OpenAlex reports 33 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

BACKGROUND: Glanzmann thrombasthenia (GT) is a rare inherited platelet disorder that is characterized by spontaneous or postprocedural bleeding. The diagnosis of GT depends on identifying the dysfunction of the platelets. AIM: The aim of this study was to compare a whole blood impedance Multiplate analyzer (MEA) with the standard method, light transmission aggregometry (LTA) in diagnosis of GT. METHODS: Fifteen patients with GT were assessed on MEA and LTA using arachidonic acid (ASPI: 15 mm), (TRAP: 1 mm), collagen (100 μg/mL), ADP (0.2 mm), and ristocetin (Risto: 10 mg/mL). Whole blood samples were collected in sodium citrate and hirudin vacuum, blood collection tubes and tested within 4 h. Platelet-rich plasma was used for LTA using platelet agonists (ristocetin 1.5 mg/mL) (arachidonic acid 0.5 mg/mL) (ADP 2.5 mg/mL) and (collagen 1 mg/mL). RESULTS: The platelet count and PFA-100 results were (average and SD) 319 ± 93 × 10(9) L and 252 ± 34 s, respectively. Flow cytometry analysis showed that all samples are positive for CD42a and CD42b, whereas 9/15 samples were negative for CD61 and CD41. The other six patients had either partial or full expression of CD61/CD41. Aggregation analysis using both methods showed that all samples had no aggregation response to any of the agonists used apart from six samples which, using only the MEA, showed minimal aggregation in response to collagen (average = 14.3 ± 7 μg, which may suggest ability to detect qualitative abnormality of GPIIb/IIIa). CONCLUSION: These results suggest that the MEA is sensitive for the detection of Glanzmann thrombasthenia. Furthermore, MEA may also be able to differentiate between the subtypes of Glanzmann thrombasthenia.

Key concepts: Thrombasthenia, Ristocetin, Platelet, Glanzmann's thrombasthenia, Whole blood, Chemistry, Platelet membrane glycoprotein, Bleeding time

Related papers

Back to paper searchBrowse research topicsOriginal source
Diagnosis of Glanzmann thrombasthenia by whole blood impedance analyzer ( MEA ) vs. light transmission aggregometry — Research Paper | ScholarLens