2008OrbitRequires access

Polyethylene Gel in the Subcutaneous Tissue of Rats: Histopathologic and Systemic Evaluation

Silvana Artioli Schellini, Gislaine Priscila Momm Zimmermann, Érika Hoyama, Claudia H. Pellizon, Carlos Roberto Padovani, Dinesh Selva

Open publisher page 4 citations

Abstract

PURPOSE: To evaluate the histological and systemic response to subcutaneous injection of polyethylene gel in rats. METHODS: Twenty-one white male rats were divided into 3 groups (G): G1 and G2 received subcutaneous polyethylene gel injection in the dorsal midline and were sacrificed at 30 and 60 postoperative days, respectively. G3 was not exposed to the polyethylene gel and was sacrificed after 60 days. Blood levels of lactate dehydrogenase (LDH), creatine kinase (CK), and alkaline phosphatase (ALP) were evaluated. The heart, kidney, liver, adrenal gland, injection site, and adjacent tissues were histologically examined. The results were submitted to statistical analysis. RESULTS: There was no clinical evidence of extrusion, reduction of the injected volume, or abnormalities in the adjacent tissues. Blood levels of CK and LDH were normal and similar in all groups. ALP levels were significantly lower in G2 than in G1 and G3. The systemic organs were normal on histological examination in the 3 groups evaluated. Microscopically, the polyethylene gel was surrounded by a thin pseudocapsule formation and minimal inflammatory cell response, which decreased from G1 to G2. CONCLUSION: The subcutaneous injection of polyethylene gel in rats elicited minimal local inflammatory response and no systemic side effects.

About this research paper

What this paper is about

PURPOSE: To evaluate the histological and systemic response to subcutaneous injection of polyethylene gel in rats. METHODS: Twenty-one white male rats were divided into 3 groups (G): G1 and G2 received subcutaneous polyethylene gel injection in the dorsal midline and were sacrificed at 30 and 60 postoperative days, respectively. G3 was not exposed to the polyethylene gel and was sacrificed after 60 days. Blood levels of lactate dehydrogenase (LDH), creatine kinase (CK), and alkaline phosphatase (ALP) were evaluated. The heart, kidney, liver, adrenal gland, injection site, and adjacent tissues were histologically examined. The results were submitted to statistical analysis. RESULTS: There was no clinical evidence of extrusion, reduction of the injected volume, or abnormalities in the adjacent tissues. Blood levels of CK and LDH were normal and similar in all groups. ALP levels were significantly lower in G2 than in G1 and G3. The systemic organs were normal on histological examination in the 3 groups evaluated. Microscopically, the polyethylene gel was surrounded by a thin pseudocapsule formation and minimal inflammatory cell response, which decreased from G1 to G2. CONCLUSION: The subcutaneous injection of polyethylene gel in rats elicited minimal local inflammatory response and no systemic side effects.

Why it matters

OpenAlex reports 4 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

PURPOSE: To evaluate the histological and systemic response to subcutaneous injection of polyethylene gel in rats. METHODS: Twenty-one white male rats were divided into 3 groups (G): G1 and G2 received subcutaneous polyethylene gel injection in the dorsal midline and were sacrificed at 30 and 60 postoperative days, respectively. G3 was not exposed to the polyethylene gel and was sacrificed after 60 days. Blood levels of lactate dehydrogenase (LDH), creatine kinase (CK), and alkaline phosphatase (ALP) were evaluated. The heart, kidney, liver, adrenal gland, injection site, and adjacent tissues were histologically examined. The results were submitted to statistical analysis. RESULTS: There was no clinical evidence of extrusion, reduction of the injected volume, or abnormalities in the adjacent tissues. Blood levels of CK and LDH were normal and similar in all groups. ALP levels were significantly lower in G2 than in G1 and G3. The systemic organs were normal on histological examination in the 3 groups evaluated. Microscopically, the polyethylene gel was surrounded by a thin pseudocapsule formation and minimal inflammatory cell response, which decreased from G1 to G2. CONCLUSION: The subcutaneous injection of polyethylene gel in rats elicited minimal local inflammatory response and no systemic side effects.

Key concepts: Medicine, Lactate dehydrogenase, Subcutaneous injection, Pathology, Alkaline phosphatase, Subcutaneous tissue, Creatine kinase, Internal medicine

Related papers

Back to paper searchBrowse research topicsOriginal source
Polyethylene Gel in the Subcutaneous Tissue of Rats: Histopathologic and Systemic Evaluation — Research Paper | ScholarLens