1976•IEEE Transactions on Nuclear ScienceRequires access

The Emittance and Brightness of Ion Beams from a PIG Ion Source with End Extraction

H. Baumann, Κ. Bethge, G. Klein

Open publisher page 2 citations

Abstract

The emittance of positive ion beams extracted from a PIG ion source with end extraction was measured for optimal operating conditions of the source at different positions of the beam line. The source was operated with noble gases in a high voltage - low current discharge mode. The results showed that the emittances increase with increasing ion mass and intensity of the ion beam and furthermore under the influence of the space charge of the beam with the distance from the source. For ion beam intensities of 1 mA values of the emittance were obtained between 0,4 and 1,1 cm mrad MeV1/2 at a distance of 10 cm behind the extraction region. The brightness varied from 0,15 to 1,3 mA cm-2 mrad-2 MeV.

About this research paper

What this paper is about

The emittance of positive ion beams extracted from a PIG ion source with end extraction was measured for optimal operating conditions of the source at different positions of the beam line. The source was operated with noble gases in a high voltage - low current discharge mode. The results showed that the emittances increase with increasing ion mass and intensity of the ion beam and furthermore under the influence of the space charge of the beam with the distance from the source. For ion beam intensities of 1 mA values of the emittance were obtained between 0,4 and 1,1 cm mrad MeV1/2 at a distance of 10 cm behind the extraction region. The brightness varied from 0,15 to 1,3 mA cm-2 mrad-2 MeV.

Why it matters

OpenAlex reports 2 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The emittance of positive ion beams extracted from a PIG ion source with end extraction was measured for optimal operating conditions of the source at different positions of the beam line. The source was operated with noble gases in a high voltage - low current discharge mode. The results showed that the emittances increase with increasing ion mass and intensity of the ion beam and furthermore under the influence of the space charge of the beam with the distance from the source. For ion beam intensities of 1 mA values of the emittance were obtained between 0,4 and 1,1 cm mrad MeV1/2 at a distance of 10 cm behind the extraction region. The brightness varied from 0,15 to 1,3 mA cm-2 mrad-2 MeV.

Key concepts: Thermal emittance, Ion source, Beam emittance, Ion, Ion beam, Beam (structure), Brightness, Ion beam deposition

Related papers

Back to paper searchBrowse research topicsOriginal source
The Emittance and Brightness of Ion Beams from a PIG Ion Source with End Extraction — Research Paper | ScholarLens