1973Journal of Polymer Science Polymer Physics EditionRequires access

High‐resolution gel‐permeation chromatography

Yoshio Kato, Shiro Kido, Tsutomu Hashimoto

Open publisher page 27 citations

Abstract

Abstract The resolution attainable in gel‐permeation chromatography (GPC) was investigated by using columns packed with polystyrene gel particles of about 5 μ diameter and mixtures of two monodisperse poly‐α‐methylstyrene samples studied previously. The resolution of GPC was found comparable to that of the sedimentation velocity method and slightly better than that of precipitation chromatography. Standard polystyrene samples obtained from Pressure Chemical Co. also were measured with the same columns. It was found that weight‐average to number‐average molecular weight ratios (M̄w/M̄n) of these samples with molecular weight in the range 97,000–411,000 are smaller than 1.006. For samples with molecular weight of 10,000–51,000 and 498,000–860,000, M̄w/M̄n is larger than 1.006, and the width of molecular weight distributions of these samples differed. In particular, molecular weight distributions of samples with molecular weights 19,800 and 51,000 were shown to be bimodal. It is therefore concluded that GPC is useful for samples of very narrow molecular weight distribution if high‐resolution columns are used.

About this research paper

What this paper is about

Abstract The resolution attainable in gel‐permeation chromatography (GPC) was investigated by using columns packed with polystyrene gel particles of about 5 μ diameter and mixtures of two monodisperse poly‐α‐methylstyrene samples studied previously. The resolution of GPC was found comparable to that of the sedimentation velocity method and slightly better than that of precipitation chromatography. Standard polystyrene samples obtained from Pressure Chemical Co. also were measured with the same columns. It was found that weight‐average to number‐average molecular weight ratios (M̄w/M̄n) of these samples with molecular weight in the range 97,000–411,000 are smaller than 1.006. For samples with molecular weight of 10,000–51,000 and 498,000–860,000, M̄w/M̄n is larger than 1.006, and the width of molecular weight distributions of these samples differed. In particular, molecular weight distributions of samples with molecular weights 19,800 and 51,000 were shown to be bimodal. It is therefore concluded that GPC is useful for samples of very narrow molecular weight distribution if high‐resolution columns are used.

Why it matters

OpenAlex reports 27 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Abstract The resolution attainable in gel‐permeation chromatography (GPC) was investigated by using columns packed with polystyrene gel particles of about 5 μ diameter and mixtures of two monodisperse poly‐α‐methylstyrene samples studied previously. The resolution of GPC was found comparable to that of the sedimentation velocity method and slightly better than that of precipitation chromatography. Standard polystyrene samples obtained from Pressure Chemical Co. also were measured with the same columns. It was found that weight‐average to number‐average molecular weight ratios (M̄w/M̄n) of these samples with molecular weight in the range 97,000–411,000 are smaller than 1.006. For samples with molecular weight of 10,000–51,000 and 498,000–860,000, M̄w/M̄n is larger than 1.006, and the width of molecular weight distributions of these samples differed. In particular, molecular weight distributions of samples with molecular weights 19,800 and 51,000 were shown to be bimodal. It is therefore concluded that GPC is useful for samples of very narrow molecular weight distribution if high‐resolution columns are used.

Key concepts: Gel permeation chromatography, Dispersity, Polystyrene, Resolution (logic), Chromatography, Molar mass distribution, Chemistry, Analytical Chemistry (journal)

Related papers

Back to paper searchBrowse research topicsOriginal source
High‐resolution gel‐permeation chromatography — Research Paper | ScholarLens