1994Journal of Microcolumn SeparationsRequires access

Shape selectivity assessment of stationary phases in gas chromatography

Lane C. Sander, Manfred Schneider, Stephen A. Wise

Open publisher page 30 citations

Abstract

Abstract Column selectivity is examined for a series of smectic liquid crystalline columns and is compared with methyl and C18 polysiloxane columns for the separation of polycyclic aromatic hydrocarbon (PAH) isomers. A set of extended and condensed solute probes is described that provides a sensitive indication of variations in column shape selectivity. Examples of shape selectivity differences are presented for smectic liquid crystalline columns and 5% phenyl polysiloxane columns using various PAH isomer sets. Variations in selectivity have been observed among different smectic liquid crystalline columns, and this problem appears more significant than for methyl polysiloxane columns. The selectivity ration for tetraphenylmethane and p‐terphenyl provides a sensitive indication of column shape selectivity, with a change in elution order occurring between ordered (smectic liquid crystalline) columns and non‐ordered (methyl polysiloxane) columns. Shape selectivity differences indicated by this test mixture are apparent for more complex PAH isomer mixtures. Despite stationary phase selectivity variability, smectic liquid crystalline columns offer considerable potential for solving difficult separation problems involving structured solutes.

About this research paper

What this paper is about

Abstract Column selectivity is examined for a series of smectic liquid crystalline columns and is compared with methyl and C18 polysiloxane columns for the separation of polycyclic aromatic hydrocarbon (PAH) isomers. A set of extended and condensed solute probes is described that provides a sensitive indication of variations in column shape selectivity. Examples of shape selectivity differences are presented for smectic liquid crystalline columns and 5% phenyl polysiloxane columns using various PAH isomer sets. Variations in selectivity have been observed among different smectic liquid crystalline columns, and this problem appears more significant than for methyl polysiloxane columns. The selectivity ration for tetraphenylmethane and p‐terphenyl provides a sensitive indication of column shape selectivity, with a change in elution order occurring between ordered (smectic liquid crystalline) columns and non‐ordered (methyl polysiloxane) columns. Shape selectivity differences indicated by this test mixture are apparent for more complex PAH isomer mixtures. Despite stationary phase selectivity variability, smectic liquid crystalline columns offer considerable potential for solving difficult separation problems involving structured solutes.

Why it matters

OpenAlex reports 30 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Abstract Column selectivity is examined for a series of smectic liquid crystalline columns and is compared with methyl and C18 polysiloxane columns for the separation of polycyclic aromatic hydrocarbon (PAH) isomers. A set of extended and condensed solute probes is described that provides a sensitive indication of variations in column shape selectivity. Examples of shape selectivity differences are presented for smectic liquid crystalline columns and 5% phenyl polysiloxane columns using various PAH isomer sets. Variations in selectivity have been observed among different smectic liquid crystalline columns, and this problem appears more significant than for methyl polysiloxane columns. The selectivity ration for tetraphenylmethane and p‐terphenyl provides a sensitive indication of column shape selectivity, with a change in elution order occurring between ordered (smectic liquid crystalline) columns and non‐ordered (methyl polysiloxane) columns. Shape selectivity differences indicated by this test mixture are apparent for more complex PAH isomer mixtures. Despite stationary phase selectivity variability, smectic liquid crystalline columns offer considerable potential for solving difficult separation problems involving structured solutes.

Key concepts: Selectivity, Chemistry, Elution, Hydrocarbon, Chromatography, Phase (matter), Structural isomer, Gas chromatography

Related papers

Back to paper searchBrowse research topicsOriginal source
Shape selectivity assessment of stationary phases in gas chromatography — Research Paper | ScholarLens