1992American Journal of Tropical Medicine and HygieneRequires access

Rapid in Vivo Detection of Chloroquine Resistance by the Quantitative Buffy Coat Malaria Diagnosis System

B. Garin, J. J. Salun, F Peyron, J. P. Vigier, I. Busangu, Joseph B. Perrone

Open publisher page 10 citations

Abstract

The use of the Giemsa-stained thick blood smear for the diagnosis of malaria has not been supplanted since the discovery of the parasite by A. Laveran in 1880. Recently, a new direct diagnosis technique, the Quantitative Buffy Coat (QBC)* Malaria Diagnosis System, has been developed. We compared this technique with the thick blood smear diagnosis in a study of the efficacy of chloroquine therapy in Zaire. A total of 815 subjects were screened; 71 participated in the trial. They were given chloroquine at a dose of 25 mg/kg of body weight over three days and were examined for parasitemia two and seven days after treatment. Chloroquine resistance was detected in 38% of the subjects by thick blood smear and in 45% by the QBC test. Of greater interest was the time required for each diagnosis: an average of 17 min was required to examine microscopic fields with 1,000 leukocytes by thick blood smear analysis compared with less than one min by the QBC system. In addition, we did not observe diminished attention from fatigue by microscopists using the QBC system despite the large number of tests conducted. We conclude that the QBC system is an important tool for studies of drug resistance.

About this research paper

What this paper is about

The use of the Giemsa-stained thick blood smear for the diagnosis of malaria has not been supplanted since the discovery of the parasite by A. Laveran in 1880. Recently, a new direct diagnosis technique, the Quantitative Buffy Coat (QBC)* Malaria Diagnosis System, has been developed. We compared this technique with the thick blood smear diagnosis in a study of the efficacy of chloroquine therapy in Zaire. A total of 815 subjects were screened; 71 participated in the trial. They were given chloroquine at a dose of 25 mg/kg of body weight over three days and were examined for parasitemia two and seven days after treatment. Chloroquine resistance was detected in 38% of the subjects by thick blood smear and in 45% by the QBC test. Of greater interest was the time required for each diagnosis: an average of 17 min was required to examine microscopic fields with 1,000 leukocytes by thick blood smear analysis compared with less than one min by the QBC system. In addition, we did not observe diminished attention from fatigue by microscopists using the QBC system despite the large number of tests conducted. We conclude that the QBC system is an important tool for studies of drug resistance.

Why it matters

OpenAlex reports 10 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The use of the Giemsa-stained thick blood smear for the diagnosis of malaria has not been supplanted since the discovery of the parasite by A. Laveran in 1880. Recently, a new direct diagnosis technique, the Quantitative Buffy Coat (QBC)* Malaria Diagnosis System, has been developed. We compared this technique with the thick blood smear diagnosis in a study of the efficacy of chloroquine therapy in Zaire. A total of 815 subjects were screened; 71 participated in the trial. They were given chloroquine at a dose of 25 mg/kg of body weight over three days and were examined for parasitemia two and seven days after treatment. Chloroquine resistance was detected in 38% of the subjects by thick blood smear and in 45% by the QBC test. Of greater interest was the time required for each diagnosis: an average of 17 min was required to examine microscopic fields with 1,000 leukocytes by thick blood smear analysis compared with less than one min by the QBC system. In addition, we did not observe diminished attention from fatigue by microscopists using the QBC system despite the large number of tests conducted. We conclude that the QBC system is an important tool for studies of drug resistance.

Key concepts: Buffy coat, Malaria, Chloroquine, Virology, Protozoal disease, In vivo, Coat, Biology

Related papers

Back to paper searchBrowse research topicsOriginal source
Rapid in Vivo Detection of Chloroquine Resistance by the Quantitative Buffy Coat Malaria Diagnosis System — Research Paper | ScholarLens