Gas Chromatographic Determination of Parathion and Paraoxon in Fish Plasma and Tissues
Richat Abbas, William L. Hayton
Abstract
Open-access reader
Richat Abbas, William L. Hayton
Abstract
Open-access reader
A sensitive capillary gas chromatographic (GC) method for the simultaneous determination of the organophosphate insecticide, parathion, and its active metabolite, paraoxon, in biological samples was developed. This method involved a simple liquid-liquid extraction of parathion and paraoxon from water, plasma, or tissues and capillary GC determination using electron-capture detection and splitless injection; malathion was used as the internal standard. A gradient oven temperature program was used; the injection port and detector temperatures were 200 and 300 degrees C, respectively. These techniques allowed quantitative determination of parathion and paraoxon at 9-210-ng/ml. concentrations;recoveries ranged from 79.4 to 110.3% for tissues and from 91.9 to 100.0% for plasma and water. The within-day and between-day coefficients of variation were less than 8.0%. The method was used to characterize the pharmacokinetics of parathion and paraoxon and the tissue distribution of paraoxon in rainbow trout.
OpenAlex reports 9 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
A sensitive capillary gas chromatographic (GC) method for the simultaneous determination of the organophosphate insecticide, parathion, and its active metabolite, paraoxon, in biological samples was developed. This method involved a simple liquid-liquid extraction of parathion and paraoxon from water, plasma, or tissues and capillary GC determination using electron-capture detection and splitless injection; malathion was used as the internal standard. A gradient oven temperature program was used; the injection port and detector temperatures were 200 and 300 degrees C, respectively. These techniques allowed quantitative determination of parathion and paraoxon at 9-210-ng/ml. concentrations;recoveries ranged from 79.4 to 110.3% for tissues and from 91.9 to 100.0% for plasma and water. The within-day and between-day coefficients of variation were less than 8.0%. The method was used to characterize the pharmacokinetics of parathion and paraoxon and the tissue distribution of paraoxon in rainbow trout.
Key concepts: Paraoxon, Parathion, Chromatography, Chemistry, Electron capture detector, Gas chromatography, Metabolite, Extraction (chemistry)