Electrode Misdirection into the Superior Semicircular Canal: Complication of Cochlear Implantation by Round Window Approach

Minbum Kim, Won Sun Yang, Ju Hyun Jeon, Jae Young Choi

Open full text 3 citations

Abstract

Abstract OBJECTIVE: The purposes of this study were to investigate the misdirection of the electrode into the superior semicircular canal during cochlear implantation and to suggest surgical principles for correct electrode insertion through the round window membrane. MATERIALS and METHODS: In this retrospective case review, operative records and postoperative images of cochlear implantations performed at a tertiary care facility from 1988 to 2010 were reviewed. RESULTS: In 3 out of 629 cases, electrode insertion into the superior semicircular canal was found. All 3 cases occurred in cochlear implantations using the round window approach, and none was found when using the cochleostomy approach. Insufficient exposure of the round window membrane and intra-cochlear soft tissue were regarded as the cause of misdirection of the electrode. The electrodes were repositioned appropriately into the cochlea with revision surgery in all 3 cases. CONCLUSION: In order to prevent electrode misdirection during cochlear implantation through the round window, the round window membrane needs to be clearly visualized by sufficiently drilling bony overhangs and removing soft tissues around the round window.

About this research paper

What this paper is about

Abstract OBJECTIVE: The purposes of this study were to investigate the misdirection of the electrode into the superior semicircular canal during cochlear implantation and to suggest surgical principles for correct electrode insertion through the round window membrane. MATERIALS and METHODS: In this retrospective case review, operative records and postoperative images of cochlear implantations performed at a tertiary care facility from 1988 to 2010 were reviewed. RESULTS: In 3 out of 629 cases, electrode insertion into the superior semicircular canal was found. All 3 cases occurred in cochlear implantations using the round window approach, and none was found when using the cochleostomy approach. Insufficient exposure of the round window membrane and intra-cochlear soft tissue were regarded as the cause of misdirection of the electrode. The electrodes were repositioned appropriately into the cochlea with revision surgery in all 3 cases. CONCLUSION: In order to prevent electrode misdirection during cochlear implantation through the round window, the round window membrane needs to be clearly visualized by sufficiently drilling bony overhangs and removing soft tissues around the round window.

Why it matters

OpenAlex reports 3 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Abstract OBJECTIVE: The purposes of this study were to investigate the misdirection of the electrode into the superior semicircular canal during cochlear implantation and to suggest surgical principles for correct electrode insertion through the round window membrane. MATERIALS and METHODS: In this retrospective case review, operative records and postoperative images of cochlear implantations performed at a tertiary care facility from 1988 to 2010 were reviewed. RESULTS: In 3 out of 629 cases, electrode insertion into the superior semicircular canal was found. All 3 cases occurred in cochlear implantations using the round window approach, and none was found when using the cochleostomy approach. Insufficient exposure of the round window membrane and intra-cochlear soft tissue were regarded as the cause of misdirection of the electrode. The electrodes were repositioned appropriately into the cochlea with revision surgery in all 3 cases. CONCLUSION: In order to prevent electrode misdirection during cochlear implantation through the round window, the round window membrane needs to be clearly visualized by sufficiently drilling bony overhangs and removing soft tissues around the round window.

Key concepts: Medicine, Round window, Cochlear implantation, Semicircular canal, Cochlear implant, Complication, Window (computing), Surgery

Related papers

Back to paper searchBrowse research topicsOriginal source
Electrode Misdirection into the Superior Semicircular Canal: Complication of Cochlear Implantation by Round Window Approach — Research Paper | ScholarLens