New Endoscope Shaft for Endoscopic Transsphenoidal Pituitary Surgery
Erik J. van Lindert, J. André Grotenhuis
Abstract
Erik J. van Lindert, J. André Grotenhuis
Abstract
OBJECTIVE: To describe a new endoscope shaft developed for suction-aspiration during endoscopic transsphenoidal pituitary surgery. METHODS: A custom-made shaft for a Wolf endoscope (Richard Wolf GmbH, Knittlingen, Germany) was developed with a height of 10 mm and a width of 5 mm, allowing an additional working channel for the endoscope for flexible suction tubes with a diameter of up to 10-French. RESULTS: The new shaft was used in 30 consecutive endoscopic transsphenoidal procedures for pituitary adenomas. It allowed true bimanual manipulation without having to fixate the endoscope. Tumor removal was facilitated, technical problems were not encountered, and operation time was reduced. There were no instrumentation-related complications. CONCLUSION: The new shaft improves the ergonomics of endoscopic transsphenoidal pituitary surgery in cases in which the endoscope is handheld.
OpenAlex reports 11 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
OBJECTIVE: To describe a new endoscope shaft developed for suction-aspiration during endoscopic transsphenoidal pituitary surgery. METHODS: A custom-made shaft for a Wolf endoscope (Richard Wolf GmbH, Knittlingen, Germany) was developed with a height of 10 mm and a width of 5 mm, allowing an additional working channel for the endoscope for flexible suction tubes with a diameter of up to 10-French. RESULTS: The new shaft was used in 30 consecutive endoscopic transsphenoidal procedures for pituitary adenomas. It allowed true bimanual manipulation without having to fixate the endoscope. Tumor removal was facilitated, technical problems were not encountered, and operation time was reduced. There were no instrumentation-related complications. CONCLUSION: The new shaft improves the ergonomics of endoscopic transsphenoidal pituitary surgery in cases in which the endoscope is handheld.
Key concepts: Endoscope, Medicine, Transsphenoidal surgery, Endoscopy, Surgery, Endoscopic surgery, Suction, Pituitary adenoma