1989Archives of Pediatrics and Adolescent MedicineRequires access

Pulse Oximetry in Methemoglobinemia

Mehernoor F. Watcha

Open publisher page 66 citations

Abstract

Pulse oximetry is a major improvement in the assessment of oxygenation. The device uses plethysmography and light absorbance measurements at two wavelengths to estimate oxygen saturation. It is inaccurate, however, when more than two types of hemoglobin are present. This article describes two infants with methemoglobinemia in whom pulse oximetry overestimated oxygen saturation. We discuss the mechanism of this systematic error and emphasize that pulse oximetry should not be used to estimate true oxygen saturation in the presence of methemoglobin. However, a disparity between oxygen saturation estimates by pulse oximetry and by calculations based on the arterial partial pressure of oxygen and the oxygen-hemoglobin dissociation curve can provide an important clue to the presence of such abnormal types of hemoglobins. Therapy should be based on direct measurements of oxyhemoglobin by cooximetry and not on measurements of oxygen saturation by pulse oximetry or on saturations calculated from the Pao2 and the oxyhemoglobin dissociation curve.

About this research paper

What this paper is about

Pulse oximetry is a major improvement in the assessment of oxygenation. The device uses plethysmography and light absorbance measurements at two wavelengths to estimate oxygen saturation. It is inaccurate, however, when more than two types of hemoglobin are present. This article describes two infants with methemoglobinemia in whom pulse oximetry overestimated oxygen saturation. We discuss the mechanism of this systematic error and emphasize that pulse oximetry should not be used to estimate true oxygen saturation in the presence of methemoglobin. However, a disparity between oxygen saturation estimates by pulse oximetry and by calculations based on the arterial partial pressure of oxygen and the oxygen-hemoglobin dissociation curve can provide an important clue to the presence of such abnormal types of hemoglobins. Therapy should be based on direct measurements of oxyhemoglobin by cooximetry and not on measurements of oxygen saturation by pulse oximetry or on saturations calculated from the Pao2 and the oxyhemoglobin dissociation curve.

Why it matters

OpenAlex reports 66 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Pulse oximetry is a major improvement in the assessment of oxygenation. The device uses plethysmography and light absorbance measurements at two wavelengths to estimate oxygen saturation. It is inaccurate, however, when more than two types of hemoglobin are present. This article describes two infants with methemoglobinemia in whom pulse oximetry overestimated oxygen saturation. We discuss the mechanism of this systematic error and emphasize that pulse oximetry should not be used to estimate true oxygen saturation in the presence of methemoglobin. However, a disparity between oxygen saturation estimates by pulse oximetry and by calculations based on the arterial partial pressure of oxygen and the oxygen-hemoglobin dissociation curve can provide an important clue to the presence of such abnormal types of hemoglobins. Therapy should be based on direct measurements of oxyhemoglobin by cooximetry and not on measurements of oxygen saturation by pulse oximetry or on saturations calculated from the Pao2 and the oxyhemoglobin dissociation curve.

Key concepts: Pulse oximetry, Oxygen–haemoglobin dissociation curve, Methemoglobinemia, Oxygen, Methemoglobin, Oxygenation, Oxygen saturation, Saturation (graph theory)

Related papers

Back to paper searchBrowse research topicsOriginal source