2006Clinical ChemistryOpen access

HPLC Method for 25-Hydroxyvitamin D Measurement: Comparison with Contemporary Assays

Gary L. Lensmeyer, Donald A. Wiebe, Neil Binkley, Marc K. Drezner

Open full text 241 citations

Abstract

BACKGROUND: The concentration of 25-hydroxyvitamin D [25(OH)D] in serum has been designated the functional indicator of vitamin D (VitD) nutritional status. Unfortunately, variability among 25(OH)D assays limits clinician ability to monitor VitD status, supplementation, and toxicity. METHODS: We developed an HPLC method that selectively measures 25-hydroxyvitamin D2 [25(OH)D2] and D3 [25(OH)D3] and compared this assay with a liquid chromatography-tandem mass spectrometry (LC-MS/MS) method, a competitive protein-binding assay (CPBA) on the Nichols Advantage platform, and an RIA from Diasorin. RESULTS: For the new HPLC assay, between-run CVs were 2.6%-4.9% for 25(OH)D3 and 3.2%-13% for 25(OH)D2; recoveries were 95%-102%; and the assay was linear from 5 microg/L to at least 200 microg/L. Comparison data were as follows: for HPLC vs LC-MS/MS, y = 1.01x - 4.82 microg/L (Sy/x = 4.93 microg/L; r = 0.996) for 25(OH)D3, and y = 0.902x - 0.566 microg/L (Sy/x = 2.56 microg/L; r = 0.9965 for 25(OH)D2; for HPLC vs Diasorin RIA, y = 0.709x - 5.86 microg/L (Sy/x = 7.35 microg/L; r = 0.7509); and for HPLC vs Nichols Advantage CPBA, y = 1.00x - 3.60 microg/L (Sy/x = 32.7 microg/L; r = 0.6823). CONCLUSIONS: The new HPLC method is reliable, robust, and has advantages compared with the Nichols Advantage CPBA and the Diasorin RIA. The Nichols Advantage CPBA overestimated or underestimated 25(OH)D concentrations predicated on the prevailing metabolite present in patients' sera.

Open-access reader

About this research paper

What this paper is about

BACKGROUND: The concentration of 25-hydroxyvitamin D [25(OH)D] in serum has been designated the functional indicator of vitamin D (VitD) nutritional status. Unfortunately, variability among 25(OH)D assays limits clinician ability to monitor VitD status, supplementation, and toxicity. METHODS: We developed an HPLC method that selectively measures 25-hydroxyvitamin D2 [25(OH)D2] and D3 [25(OH)D3] and compared this assay with a liquid chromatography-tandem mass spectrometry (LC-MS/MS) method, a competitive protein-binding assay (CPBA) on the Nichols Advantage platform, and an RIA from Diasorin. RESULTS: For the new HPLC assay, between-run CVs were 2.6%-4.9% for 25(OH)D3 and 3.2%-13% for 25(OH)D2; recoveries were 95%-102%; and the assay was linear from 5 microg/L to at least 200 microg/L. Comparison data were as follows: for HPLC vs LC-MS/MS, y = 1.01x - 4.82 microg/L (Sy/x = 4.93 microg/L; r = 0.996) for 25(OH)D3, and y = 0.902x - 0.566 microg/L (Sy/x = 2.56 microg/L; r = 0.9965 for 25(OH)D2; for HPLC vs Diasorin RIA, y = 0.709x - 5.86 microg/L (Sy/x = 7.35 microg/L; r = 0.7509); and for HPLC vs Nichols Advantage CPBA, y = 1.00x - 3.60 microg/L (Sy/x = 32.7 microg/L; r = 0.6823). CONCLUSIONS: The new HPLC method is reliable, robust, and has advantages compared with the Nichols Advantage CPBA and the Diasorin RIA. The Nichols Advantage CPBA overestimated or underestimated 25(OH)D concentrations predicated on the prevailing metabolite present in patients' sera.

Why it matters

OpenAlex reports 241 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

BACKGROUND: The concentration of 25-hydroxyvitamin D [25(OH)D] in serum has been designated the functional indicator of vitamin D (VitD) nutritional status. Unfortunately, variability among 25(OH)D assays limits clinician ability to monitor VitD status, supplementation, and toxicity. METHODS: We developed an HPLC method that selectively measures 25-hydroxyvitamin D2 [25(OH)D2] and D3 [25(OH)D3] and compared this assay with a liquid chromatography-tandem mass spectrometry (LC-MS/MS) method, a competitive protein-binding assay (CPBA) on the Nichols Advantage platform, and an RIA from Diasorin. RESULTS: For the new HPLC assay, between-run CVs were 2.6%-4.9% for 25(OH)D3 and 3.2%-13% for 25(OH)D2; recoveries were 95%-102%; and the assay was linear from 5 microg/L to at least 200 microg/L. Comparison data were as follows: for HPLC vs LC-MS/MS, y = 1.01x - 4.82 microg/L (Sy/x = 4.93 microg/L; r = 0.996) for 25(OH)D3, and y = 0.902x - 0.566 microg/L (Sy/x = 2.56 microg/L; r = 0.9965 for 25(OH)D2; for HPLC vs Diasorin RIA, y = 0.709x - 5.86 microg/L (Sy/x = 7.35 microg/L; r = 0.7509); and for HPLC vs Nichols Advantage CPBA, y = 1.00x - 3.60 microg/L (Sy/x = 32.7 microg/L; r = 0.6823). CONCLUSIONS: The new HPLC method is reliable, robust, and has advantages compared with the Nichols Advantage CPBA and the Diasorin RIA. The Nichols Advantage CPBA overestimated or underestimated 25(OH)D concentrations predicated on the prevailing metabolite present in patients' sera.

Key concepts: High-performance liquid chromatography, Chromatography, Vitamin D and neurology, Chemistry, Vitamin D-binding protein, Competitive binding, Medicine, Internal medicine

Related papers

Back to paper searchBrowse research topicsOriginal source
HPLC Method for 25-Hydroxyvitamin D Measurement: Comparison with Contemporary Assays — Research Paper | ScholarLens