2013INTERNATIONAL JOURNAL OF ADVANCED RESEARCH IN ARTIFICIAL INTELLIGENCEOpen access

Comparison Among Cross, Onboard and Vicarious Calibrations for Terra/ASTER/VNIR

Kohei Arai

Open full text 0 citations

Abstract

Comparative study on radiometric calibration methods among onboard, cross and vicarious calibration for visible to near infrared radiometers onboard satellites is conducted. The data sources of the aforementioned three calibration methods are different and independent. Therefore, it may say that the reliable Radiometric Calibration Accuracy: RCC would be the RCC which are resemble each other two of three RCCs. As experimental results, it is found that vicarious and cross calibration are reliable than onboard calibration. Also vicarious calibration based cross calibration method is proposed here. The proposed cross calibration method should be superior to the conventional cross calibration method based on band-to-band data comparison. Through experiments, it is also found that the proposed cross calibration is better than the conventional cross calibration. The radiometric calibration accuracy of the conventional cross calibration method can be evaluated by using the proposed cross calibration method.

Open-access reader

About this research paper

What this paper is about

Comparative study on radiometric calibration methods among onboard, cross and vicarious calibration for visible to near infrared radiometers onboard satellites is conducted. The data sources of the aforementioned three calibration methods are different and independent. Therefore, it may say that the reliable Radiometric Calibration Accuracy: RCC would be the RCC which are resemble each other two of three RCCs. As experimental results, it is found that vicarious and cross calibration are reliable than onboard calibration. Also vicarious calibration based cross calibration method is proposed here. The proposed cross calibration method should be superior to the conventional cross calibration method based on band-to-band data comparison. Through experiments, it is also found that the proposed cross calibration is better than the conventional cross calibration. The radiometric calibration accuracy of the conventional cross calibration method can be evaluated by using the proposed cross calibration method.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Comparative study on radiometric calibration methods among onboard, cross and vicarious calibration for visible to near infrared radiometers onboard satellites is conducted. The data sources of the aforementioned three calibration methods are different and independent. Therefore, it may say that the reliable Radiometric Calibration Accuracy: RCC would be the RCC which are resemble each other two of three RCCs. As experimental results, it is found that vicarious and cross calibration are reliable than onboard calibration. Also vicarious calibration based cross calibration method is proposed here. The proposed cross calibration method should be superior to the conventional cross calibration method based on band-to-band data comparison. Through experiments, it is also found that the proposed cross calibration is better than the conventional cross calibration. The radiometric calibration accuracy of the conventional cross calibration method can be evaluated by using the proposed cross calibration method.

Key concepts: VNIR, Remote sensing, Calibration, Radiometer, Radiometric calibration, Advanced Spaceborne Thermal Emission and Reflection Radiometer, Computer science, Environmental science

Related papers

Back to paper searchBrowse research topicsOriginal source
Comparison Among Cross, Onboard and Vicarious Calibrations for Terra/ASTER/VNIR — Research Paper | ScholarLens