2012Japanese Journal of Clinical OncologyRequires access

Defining PET Standardized Uptake Value Threshold for Tumor Delineation with Metastatic Lymph Nodes in Head and Neck Cancer

Осаму Сузукі, K Nishiyama, Masahiro Morimoto, H. Hashiguchi, Kentaro Tanaka, Aya Nakajima, Satoaki Nakamura, Kiyoshi Yoshino

Open publisher page 5 citations

Abstract

OBJECTIVE: Hot spots of F-18 fluorodeoxyglucose positron emission tomograms are variable in size according to window settings of standardized uptake values. The purpose of this study was to determine the standardized uptake value threshold that represents the target volume. METHODS: Sixty-three patients who underwent fluorodeoxyglucose positron emission tomographic computed tomography and were diagnosed as having head and neck cancer with cervical lymphadenopathy were studied. The horizontal and vertical diameters of metastatic lymph nodes (LN-CT) were measured at the center of computed tomographic images. Of the corresponding nodes, the maximal standardized uptake value (SUVmax) and standardized uptake value profiles along the central horizontal and vertical axes were calculated on positron emission tomographic images (LN-PET). On the standardized uptake value profiles, the standardized uptake value levels (SUVeq) where the size of LN-PET was equivalent to the diameters of LN-CT were obtained. The regression formula between SUVeq and SUVmax was obtained. The regression formula of SUVeq was validated in subsequent 30 positron emission tomographic computed tomography studies. RESULTS: The mean horizontal and vertical diameters of LN-CT were 14.9 and 16.4 mm, respectively. SUVmax ranged from 1.88 to 9.07, and SUVeq was between 1.16 and 6.42. The regression formula between SUVeq and SUVmax was as follows: SUVeq = 1.21 + 0.34 × SUVmax (coefficient of correlation: R = 0.69). The validation study resulted in a good correlation between the volume of lymph nodes on computed tomography and positron emission tomographic computed tomography (R(2) = 0.93). CONCLUSIONS: The formula with a relatively high coefficient of correlation is considered to indicate that SUVeq is not constant, but is a complex of an absolute standardized uptake value and is proportional to SUVmax.

About this research paper

What this paper is about

OBJECTIVE: Hot spots of F-18 fluorodeoxyglucose positron emission tomograms are variable in size according to window settings of standardized uptake values. The purpose of this study was to determine the standardized uptake value threshold that represents the target volume. METHODS: Sixty-three patients who underwent fluorodeoxyglucose positron emission tomographic computed tomography and were diagnosed as having head and neck cancer with cervical lymphadenopathy were studied. The horizontal and vertical diameters of metastatic lymph nodes (LN-CT) were measured at the center of computed tomographic images. Of the corresponding nodes, the maximal standardized uptake value (SUVmax) and standardized uptake value profiles along the central horizontal and vertical axes were calculated on positron emission tomographic images (LN-PET). On the standardized uptake value profiles, the standardized uptake value levels (SUVeq) where the size of LN-PET was equivalent to the diameters of LN-CT were obtained. The regression formula between SUVeq and SUVmax was obtained. The regression formula of SUVeq was validated in subsequent 30 positron emission tomographic computed tomography studies. RESULTS: The mean horizontal and vertical diameters of LN-CT were 14.9 and 16.4 mm, respectively. SUVmax ranged from 1.88 to 9.07, and SUVeq was between 1.16 and 6.42. The regression formula between SUVeq and SUVmax was as follows: SUVeq = 1.21 + 0.34 × SUVmax (coefficient of correlation: R = 0.69). The validation study resulted in a good correlation between the volume of lymph nodes on computed tomography and positron emission tomographic computed tomography (R(2) = 0.93). CONCLUSIONS: The formula with a relatively high coefficient of correlation is considered to indicate that SUVeq is not constant, but is a complex of an absolute standardized uptake value and is proportional to SUVmax.

Why it matters

OpenAlex reports 5 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

OBJECTIVE: Hot spots of F-18 fluorodeoxyglucose positron emission tomograms are variable in size according to window settings of standardized uptake values. The purpose of this study was to determine the standardized uptake value threshold that represents the target volume. METHODS: Sixty-three patients who underwent fluorodeoxyglucose positron emission tomographic computed tomography and were diagnosed as having head and neck cancer with cervical lymphadenopathy were studied. The horizontal and vertical diameters of metastatic lymph nodes (LN-CT) were measured at the center of computed tomographic images. Of the corresponding nodes, the maximal standardized uptake value (SUVmax) and standardized uptake value profiles along the central horizontal and vertical axes were calculated on positron emission tomographic images (LN-PET). On the standardized uptake value profiles, the standardized uptake value levels (SUVeq) where the size of LN-PET was equivalent to the diameters of LN-CT were obtained. The regression formula between SUVeq and SUVmax was obtained. The regression formula of SUVeq was validated in subsequent 30 positron emission tomographic computed tomography studies. RESULTS: The mean horizontal and vertical diameters of LN-CT were 14.9 and 16.4 mm, respectively. SUVmax ranged from 1.88 to 9.07, and SUVeq was between 1.16 and 6.42. The regression formula between SUVeq and SUVmax was as follows: SUVeq = 1.21 + 0.34 × SUVmax (coefficient of correlation: R = 0.69). The validation study resulted in a good correlation between the volume of lymph nodes on computed tomography and positron emission tomographic computed tomography (R(2) = 0.93). CONCLUSIONS: The formula with a relatively high coefficient of correlation is considered to indicate that SUVeq is not constant, but is a complex of an absolute standardized uptake value and is proportional to SUVmax.

Key concepts: Standardized uptake value, Positron emission tomography, Nuclear medicine, Medicine, Positron emission, Tomography, Fluorodeoxyglucose, Head and neck cancer

Related papers

Back to paper searchBrowse research topicsOriginal source
Defining PET Standardized Uptake Value Threshold for Tumor Delineation with Metastatic Lymph Nodes in Head and Neck Cancer — Research Paper | ScholarLens