2010Clinical and Experimental OphthalmologyRequires access

Assessment of optic disc parameters among healthy adult Malays by Heidelberg Retinal Tomograph II

Shawarinin Binti Jusoh, Bakiah Shaharuddin, Wan Hazabbah Wan Hitam

Open publisher page 0 citations

Abstract

BACKGROUND: This study aims to assess the optic disc characteristics in healthy adult Malays and to correlate them with age, gender and refractive errors. DESIGN: Cross-sectional study. PARTICIPANTS: A total of 200 voluntary participants (106 women and 94 men) among Malay students aged 20 to 37 years at Health Campus, Universiti Sains Malaysia. METHODS: The relationship between Heidelberg Retinal Tomograph parameters with age, gender and refractive error were analysed with correlation tests and multiple linear regression analyses. MAIN OUTCOME MEASURES: Twelve parameters, that is, disc area, rim area, cup area, cup to disc area, cup volume, rim volume, height variation contour, cup shape measure, mean cup depth, maximum cup depth, mean retinal nerve fibre layer thickness and retinal nerve fibre layer cross-sectional area. RESULTS: Disc area, rim area and cup : disc area ratio averaged 2.24 ± 0.52 (mean ± standard deviation), 1.64 ± 0.32 and 0.25 ± 0.12 mm(2) , respectively. Five parameters (disc area, cup area, cup volume, cup : disc area ratio and mean retinal nerve fibre layer thickness) showed statistically significant difference between men and women. Age was negatively and significantly correlated with rim area with coefficient r = -0.21, P = 0.003. All optic disc parameters were significantly correlated (P < 0.05) with disc area, except cup shape measure. CONCLUSIONS: One or more of optic disc parameters were affected significantly by age, gender and disc area in healthy adult Malays' eyes. These factors need to be considered during the evaluation of optic disc.

About this research paper

What this paper is about

BACKGROUND: This study aims to assess the optic disc characteristics in healthy adult Malays and to correlate them with age, gender and refractive errors. DESIGN: Cross-sectional study. PARTICIPANTS: A total of 200 voluntary participants (106 women and 94 men) among Malay students aged 20 to 37 years at Health Campus, Universiti Sains Malaysia. METHODS: The relationship between Heidelberg Retinal Tomograph parameters with age, gender and refractive error were analysed with correlation tests and multiple linear regression analyses. MAIN OUTCOME MEASURES: Twelve parameters, that is, disc area, rim area, cup area, cup to disc area, cup volume, rim volume, height variation contour, cup shape measure, mean cup depth, maximum cup depth, mean retinal nerve fibre layer thickness and retinal nerve fibre layer cross-sectional area. RESULTS: Disc area, rim area and cup : disc area ratio averaged 2.24 ± 0.52 (mean ± standard deviation), 1.64 ± 0.32 and 0.25 ± 0.12 mm(2) , respectively. Five parameters (disc area, cup area, cup volume, cup : disc area ratio and mean retinal nerve fibre layer thickness) showed statistically significant difference between men and women. Age was negatively and significantly correlated with rim area with coefficient r = -0.21, P = 0.003. All optic disc parameters were significantly correlated (P < 0.05) with disc area, except cup shape measure. CONCLUSIONS: One or more of optic disc parameters were affected significantly by age, gender and disc area in healthy adult Malays' eyes. These factors need to be considered during the evaluation of optic disc.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

BACKGROUND: This study aims to assess the optic disc characteristics in healthy adult Malays and to correlate them with age, gender and refractive errors. DESIGN: Cross-sectional study. PARTICIPANTS: A total of 200 voluntary participants (106 women and 94 men) among Malay students aged 20 to 37 years at Health Campus, Universiti Sains Malaysia. METHODS: The relationship between Heidelberg Retinal Tomograph parameters with age, gender and refractive error were analysed with correlation tests and multiple linear regression analyses. MAIN OUTCOME MEASURES: Twelve parameters, that is, disc area, rim area, cup area, cup to disc area, cup volume, rim volume, height variation contour, cup shape measure, mean cup depth, maximum cup depth, mean retinal nerve fibre layer thickness and retinal nerve fibre layer cross-sectional area. RESULTS: Disc area, rim area and cup : disc area ratio averaged 2.24 ± 0.52 (mean ± standard deviation), 1.64 ± 0.32 and 0.25 ± 0.12 mm(2) , respectively. Five parameters (disc area, cup area, cup volume, cup : disc area ratio and mean retinal nerve fibre layer thickness) showed statistically significant difference between men and women. Age was negatively and significantly correlated with rim area with coefficient r = -0.21, P = 0.003. All optic disc parameters were significantly correlated (P < 0.05) with disc area, except cup shape measure. CONCLUSIONS: One or more of optic disc parameters were affected significantly by age, gender and disc area in healthy adult Malays' eyes. These factors need to be considered during the evaluation of optic disc.

Key concepts: Optic disc, Medicine, Ophthalmology, Retinal, Refractive error, Nerve fiber layer, Optic nerve, Linear regression

Related papers

Back to paper searchBrowse research topicsOriginal source
Assessment of optic disc parameters among healthy adult Malays by Heidelberg Retinal Tomograph II — Research Paper | ScholarLens