2008Pediatrics InternationalRequires access

Cardiac output and blood volume parameters using femoral arterial thermodilution

Jesús López‐Herce, Amaya Bustinza, Luis Sancho, Santiago Mencía, Ángel Carrillo, Ramón Moral, José M. Bellón

Open publisher page 32 citations

Abstract

BACKGROUND: The pulse-induced continuous cardiac output (PiCCO) system is a less invasive method than pulmonary thermodilution for the measurement of cardiac output and estimating blood volume parameters. The normal values in children have not been defined. The purpose of the present paper was therefore to evaluate cardiac output and parameters of blood volume using femoral arterial thermodilution in critically ill children. METHODS: A prospective study was performed in 17 critically ill children aged between 2 months and 14 years. Two measurements were taken for each determination of cardiac output, global end diastolic volume (GEDVI), intrathoracic blood volume index (ITBI), extravascular lung water index (ELWI), systolic volume index (SVI), stroke volume variation (SVV), cardiac function index (CFI), left ventricular contractility (dp/dt max), and the systemic vascular resistance index (SVRI). RESULTS: One hundred and seventeen measurements were performed. The mean cardiac index (CI) was 3.5 +/- 1.3 L/min per m(2). The GEDVI (399.7 +/- 349.1 mL/m(2)), ITBI (574.5 +/- 212.2 mL/m(2)) and dp/dt max (804.6 +/- 372.1 mmHg/s) were lower than reported in adults, whereas ELWI (18.9 +/- 9.3 mL/m2) and CFI (8 +/- 2.5 L/min) where higher. The GEDVI, SVI, dp/dt max and CI increased with the weight of the patients whereas the ELWI values decreased. CONCLUSIONS: Femoral arterial thermodilution is a suitable technique for the measurement of cardiac output in critically ill children. The intrathoracic and intracardiac volumes are lower than in adults, whereas extrapulmonary water is higher; these values are related to the weight of the patient.

About this research paper

What this paper is about

BACKGROUND: The pulse-induced continuous cardiac output (PiCCO) system is a less invasive method than pulmonary thermodilution for the measurement of cardiac output and estimating blood volume parameters. The normal values in children have not been defined. The purpose of the present paper was therefore to evaluate cardiac output and parameters of blood volume using femoral arterial thermodilution in critically ill children. METHODS: A prospective study was performed in 17 critically ill children aged between 2 months and 14 years. Two measurements were taken for each determination of cardiac output, global end diastolic volume (GEDVI), intrathoracic blood volume index (ITBI), extravascular lung water index (ELWI), systolic volume index (SVI), stroke volume variation (SVV), cardiac function index (CFI), left ventricular contractility (dp/dt max), and the systemic vascular resistance index (SVRI). RESULTS: One hundred and seventeen measurements were performed. The mean cardiac index (CI) was 3.5 +/- 1.3 L/min per m(2). The GEDVI (399.7 +/- 349.1 mL/m(2)), ITBI (574.5 +/- 212.2 mL/m(2)) and dp/dt max (804.6 +/- 372.1 mmHg/s) were lower than reported in adults, whereas ELWI (18.9 +/- 9.3 mL/m2) and CFI (8 +/- 2.5 L/min) where higher. The GEDVI, SVI, dp/dt max and CI increased with the weight of the patients whereas the ELWI values decreased. CONCLUSIONS: Femoral arterial thermodilution is a suitable technique for the measurement of cardiac output in critically ill children. The intrathoracic and intracardiac volumes are lower than in adults, whereas extrapulmonary water is higher; these values are related to the weight of the patient.

Why it matters

OpenAlex reports 32 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

BACKGROUND: The pulse-induced continuous cardiac output (PiCCO) system is a less invasive method than pulmonary thermodilution for the measurement of cardiac output and estimating blood volume parameters. The normal values in children have not been defined. The purpose of the present paper was therefore to evaluate cardiac output and parameters of blood volume using femoral arterial thermodilution in critically ill children. METHODS: A prospective study was performed in 17 critically ill children aged between 2 months and 14 years. Two measurements were taken for each determination of cardiac output, global end diastolic volume (GEDVI), intrathoracic blood volume index (ITBI), extravascular lung water index (ELWI), systolic volume index (SVI), stroke volume variation (SVV), cardiac function index (CFI), left ventricular contractility (dp/dt max), and the systemic vascular resistance index (SVRI). RESULTS: One hundred and seventeen measurements were performed. The mean cardiac index (CI) was 3.5 +/- 1.3 L/min per m(2). The GEDVI (399.7 +/- 349.1 mL/m(2)), ITBI (574.5 +/- 212.2 mL/m(2)) and dp/dt max (804.6 +/- 372.1 mmHg/s) were lower than reported in adults, whereas ELWI (18.9 +/- 9.3 mL/m2) and CFI (8 +/- 2.5 L/min) where higher. The GEDVI, SVI, dp/dt max and CI increased with the weight of the patients whereas the ELWI values decreased. CONCLUSIONS: Femoral arterial thermodilution is a suitable technique for the measurement of cardiac output in critically ill children. The intrathoracic and intracardiac volumes are lower than in adults, whereas extrapulmonary water is higher; these values are related to the weight of the patient.

Key concepts: Medicine, Cardiac output, Cardiac index, Stroke volume, Vascular resistance, Cardiology, Blood volume, End-systolic volume

Related papers

Back to paper searchBrowse research topicsOriginal source
Cardiac output and blood volume parameters using femoral arterial thermodilution — Research Paper | ScholarLens